1 Question 1 Single choice Plan the low-level design
A financial services firm is replacing its aggregation layer with a pair of HPE Aruba Networking CX data center switches in a spine-leaf fabric. The high-level design requires 25 GbE server connections at each leaf, 100 GbE uplinks to the spine, and no single point of failure for any leaf pair. The site has 6 kW of power per rack, and the security team forbids any design that places management traffic on the production data VRF. The network architect is building the low-level design and must select a deployment approach for the leaf pairs that meets all requirements with the fewest changes later. Which approach should be specified?
Correct Answer: BExplanationVSX provides active-active leaf redundancy with no single point of failure, and the keepalive and ISL must run on dedicated links so that a failure of the production path does not cause a split-brain condition. Keeping management in the out-of-band management VRF satisfies the security team's constraint. A single standalone leaf violates the redundancy requirement. Carrying the ISL over production uplinks risks the data path taking down the peer link, and placing management in the data VRF breaks the stated security rule. A stacked pair with uplinks from only one member loses uplink redundancy if that member fails.
-
2 Question 2 Multiple choice Configure the solution
A healthcare provider is configuring an HPE Aruba Networking CX data center switch that will carry clinical imaging traffic. The design requires that traffic from the imaging VLAN be reachable across a routed core while the switch's physical interfaces remain in a single broadcast domain per rack. The design also requires that a monitoring server receive a copy of imaging traffic without affecting forwarding. Which two configuration elements meet these requirements? (Choose two.)
Correct Answer: B, DExplanationA VLAN interface (SVI) carries the imaging subnet into routing, which keeps the rack a single broadcast domain while making it reachable across the routed core. A mirror session on the CX platform copies traffic from a source to a monitoring destination without altering the forwarding path, which meets the monitoring requirement. Routed server ports would break the single-broadcast-domain requirement. Adding the monitoring port to the imaging VLAN would inject it into forwarding and expose the server to production traffic. Disabling spanning tree removes loop protection and is not a requirement-driven change.
-
3 Question 3 Order list Install the solution
A retail company is deploying a new pair of HPE Aruba Networking CX data center switches into a live data hall. The switches must be validated for connectivity and configuration before they are connected to production uplinks, so that no outage occurs if a cabling or configuration error exists. Arrange the steps in the correct order.
Drag the steps into the correct order, or use the arrows.
- Connect the production uplinks and server links, then confirm traffic paths end to end.
- Rack and power the switches and connect the management ports to the out-of-band network.
- Apply the staged baseline configuration and verify it against the low-level design.
- Verify that interfaces, LLDP neighbours and cabling match the documented port map.
- Connect the ISL and keepalive links and confirm the VSX peer relationship is established.
Correct Answer:- Rack and power the switches and connect the management ports to the out-of-band network.
- Apply the staged baseline configuration and verify it against the low-level design.
- Connect the ISL and keepalive links and confirm the VSX peer relationship is established.
- Verify that interfaces, LLDP neighbours and cabling match the documented port map.
- Connect the production uplinks and server links, then confirm traffic paths end to end.
ExplanationPhysical installation starts with racking, powering and out-of-band management access so the switches can be reached. The baseline configuration is staged and checked against the design before peering is brought up. The ISL and keepalive are then connected to form the VSX pair, after which the port map and neighbour discovery are validated. Production uplinks and server links are connected last, only once the switches are proven healthy, so that a cabling or configuration fault cannot cause an outage. Connecting production links before validation would expose the live network to unverified changes.
-
4 Question 4 Dropdown Troubleshoot
A data centre engineer is investigating intermittent packet loss on a server-facing port of an HPE Aruba Networking CX switch. Interface counters show growing CRC errors, and the engineer needs to confirm the port's physical status and error counters from the switch CLI before deciding whether to replace the optic or the cable. Complete the command sequence by selecting the correct value for each blank.
Choose the correct value for each blank.
switch# show interface counters errors
switch# show interface transceiver detailCorrect Answer:switch# show interface 1/1/12 counters errors
switch# show interface 1/1/12 transceiver detailExplanationOn CX switches, physical interface error counters and transceiver diagnostics are both queried against the physical port identifier, here 1/1/12, so the engineer can compare CRC error growth with optic receive and transmit power levels. The VLAN interface does not carry physical error counters, and the management port is out of band and not the server-facing port in question. A link aggregation group would show aggregated counters rather than the individual member's optic data. Using the physical port identifier for both commands gives the evidence needed to choose between optic and cable replacement.
-
5 Question 5 Single choice Create a monitored environment
A logistics company runs an HPE Aruba Networking CX data center with 40 switches. The operations team wants to be alerted when a switch's CPU utilisation sustains high levels, but they receive frequent false alarms during nightly backup windows that normally push CPU to 80 percent for about 30 minutes. The team must establish an alert threshold that reflects normal behaviour without missing real faults, and the solution must not require manual tuning per switch every night. What should the team do first?
Correct Answer: BExplanationA baseline built from historical data shows the true pattern, including the nightly backup peak, so thresholds and sustain durations can be set above normal behaviour while still catching abnormal load. A static 60 percent threshold would keep firing during backups and generate the same false alarms. Disabling CPU alerting removes an important health signal. Nightly alert suppression is manual and error-prone, and it creates blind spots that the requirement to avoid missing real faults forbids.
-
6 Question 6 Drag and drop Integration
A cloud services provider is integrating HPE Aruba Networking CX data center switches with its virtualised hypervisor cluster and an iSCSI storage array. Each requirement must be matched to the switch capability that satisfies it. Match each requirement to the service that meets it.
Drag each item onto its matching target. On a phone: tap an item, then tap a target.
Keep storage traffic on a lossless path with priority flow control on the storage VLANLet the hypervisor move virtual machines between hosts without manual port reconfigurationGive each tenant an isolated routing domain on shared physical switchesStatic MAC address entries on every host portPriority-based flow control with DCB on the storage portsAutomatic VLAN and policy provisioning through a hypervisor integrationSpanning tree priority tuning on the storage VLANSeparate VRFs per tenantCorrect Answer:- Keep storage traffic on a lossless path with priority flow control on the storage VLAN → Priority-based flow control with DCB on the storage ports
- Let the hypervisor move virtual machines between hosts without manual port reconfiguration → Automatic VLAN and policy provisioning through a hypervisor integration
- Give each tenant an isolated routing domain on shared physical switches → Separate VRFs per tenant
ExplanationLossless storage transport on CX switches relies on priority-based flow control within a DCB configuration, applied to the storage ports. Hypervisor integration automates VLAN and policy provisioning so that virtual machine moves do not need manual port changes. Tenant isolation at the routing layer is achieved with separate VRFs. Spanning tree priority does not provide lossless behaviour, and static MAC entries on every host port do not scale and do not address either requirement.
-
7 Question 7 Multiple choice Maintain and optimize
A university's data centre team manages a set of HPE Aruba Networking CX switches. The licence for a required feature expires in 60 days and the team's change calendar is tight. They must avoid any loss of service when renewing, and they need to keep software current in line with the vendor's release lifecycle. Which two actions best meet these requirements? (Choose two.)
Correct Answer: C, DExplanationRenewing the subscription before expiry keeps the licensed feature active and avoids a service interruption, which is the stated constraint. Monitoring vendor release cycles and scheduling upgrades to supported releases keeps the platform current in a controlled way. Letting the licence lapse causes the feature to stop working, and upgrading immediately on release day skips validation and increases change risk. Removing the feature changes the design rather than meeting the requirement.
-
8 Question 8 Single choice Troubleshoot
An enterprise data centre has an HPE Aruba Networking CX switch that reports an unexpected reboot. The operations team must assess severity before deciding on action, and the switch carries production traffic for a financial trading application with a strict recovery time objective. Logs show a single reboot with no repeat in the last six hours, and the platform health indicators are normal. Which action should be taken first?
Correct Answer: DExplanationSeverity must be established from evidence before remediation is chosen. Reviewing the system log and crash information identifies whether the reboot was a one-off event, a hardware fault or a software defect, and comparing that against the recovery objective determines the response level. Immediate replacement and upgrading without log review commit to a remedy before the cause is known. Disabling production uplinks creates an outage of its own and is not justified by a single healthy event.
-
9 Question 9 Dropdown Configure the solution
A telecommunications company is configuring an HPE Aruba Networking CX data center switch so that an uplink interface runs LACP and is included in a link aggregation group with a stable identifier for the core. The configuration must place the LAG in a mode that actively negotiates the aggregate with the peer. Complete the configuration by selecting the correct value for each blank.
Choose the correct value for each blank.
switch(config)# interface lag
switch(config-lag-if)# lacp modeCorrect Answer:switch(config)# interface lag 10
switch(config-lag-if)# lacp mode activeExplanationThe LAG identifier is a numeric value chosen for the aggregate, and 10 is a valid choice for this design. Setting the LACP mode to active causes the switch to initiate negotiation with the peer, which is required here. Passive mode waits for the peer to initiate, and forcing a static aggregate with the on option bypasses LACP entirely, which contradicts the requirement. Disabled is not a mode that participates in negotiation.
-
10 Question 10 Drag and drop Create a monitored environment
A managed services provider is building reporting for its HPE Aruba Networking CX data center. The monitoring plan needs to show long-term capacity trends, real-time port health and a summary of switch health for a monthly review. Match each reporting need to the output that best supports it. Match each requirement to the service that meets it.
Drag each item onto its matching target. On a phone: tap an item, then tap a target.
Live view of error counters on a port during an active incidentMonth-over-month trend of interface utilisation for capacity planningSingle summary of platform health across all switches for the monthly reviewStatic configuration backup fileConsolidated health report covering all switchesRouting table snapshotHistorical utilisation report generated from collected statisticsReal-time interface counter query on the switchCorrect Answer:- Month-over-month trend of interface utilisation for capacity planning → Historical utilisation report generated from collected statistics
- Live view of error counters on a port during an active incident → Real-time interface counter query on the switch
- Single summary of platform health across all switches for the monthly review → Consolidated health report covering all switches
ExplanationCapacity planning requires historical data, so a report built from collected utilisation statistics gives the trend. Live incident troubleshooting needs current counters pulled directly from the switch. A consolidated health report across switches supports the monthly review. A static configuration backup and a routing table snapshot do not provide trend, real-time or health-summary information.
-
11 Question 11 Single choice Install the solution
A company is staging six HPE Aruba Networking CX data center switches before they are shipped to a remote data hall with limited on-site engineering. The design requires the switches to be pre-configured, tested for connectivity and confirmed to match the low-level design before shipping, with the least possible on-site work. Which staging approach best meets these requirements?
Correct Answer: BExplanationStaging in a lab against the baseline configuration allows connectivity, management access and port mapping to be validated before shipment, which minimises on-site work and aligns with the design. Shipping unconfigured units pushes configuration effort and error risk to the remote site. Connecting to production at the staging site risks impact on live services. Deferring configuration until installation removes the pre-validation the requirement calls for.
-
12 Question 12 Single choice Optimize security
A government agency runs HPE Aruba Networking CX data center switches that host both administrative and citizen-facing services. An audit found that administrative access to the switches uses the same credentials for all engineers, and the agency must enforce individual accountability and least privilege while keeping an emergency recovery path if the central authentication service is unavailable. Which configuration best meets these requirements?
Correct Answer: BExplanationIndividual accounts from the central directory provide accountability, and role-based permissions enforce least privilege. A separate local emergency account with restricted rights preserves recovery access if the directory is unavailable, without reintroducing a shared or over-privileged account. A weekly password change on a shared account does nothing for accountability. Full rights for every engineer violates least privilege. Removing local accounts entirely creates a recovery gap during directory failure, which the requirement explicitly forbids.
-
13 Question 13 Order list Optimize security
A bank's data centre team is hardening a set of HPE Aruba Networking CX switches to limit management access to authorised networks only. The change must be made without locking the team out of the switches during the process. Arrange the steps in the correct order.
Drag the steps into the correct order, or use the arrows.
- Define the permitted management subnets and create an access rule that allows only those sources.
- Save the configuration and document the change in the operations record.
- Verify that the administrator's management workstation can reach the switches from the permitted management subnet.
- Apply the access rule to the management interface and confirm the change in a test session.
- Remove the broad management access rule after the restricted rule is confirmed working.
Correct Answer:- Verify that the administrator's management workstation can reach the switches from the permitted management subnet.
- Define the permitted management subnets and create an access rule that allows only those sources.
- Apply the access rule to the management interface and confirm the change in a test session.
- Remove the broad management access rule after the restricted rule is confirmed working.
- Save the configuration and document the change in the operations record.
ExplanationConfirming reachability from the permitted management subnet comes before any restriction is applied, so the team does not lock itself out. The restricted access rule is defined and then applied to the management interface, and a test session confirms that access still works. Only after that is the broad rule removed, and the configuration is then saved and documented. Removing the broad rule before validation would risk the lockout the requirement forbids.
-
14 Question 14 Multiple choice Optimize traffic
A media company runs an HPE Aruba Networking CX data center where a video ingestion service sends large, bursty flows that cause congestion on a shared leaf uplink. The company needs to protect latency-sensitive control traffic on the same links and reduce queue buildup without adding hardware. Which two actions best meet these requirements? (Choose two.)
Correct Answer: A, BExplanationQoS classification with scheduling lets control traffic be serviced ahead of bulk flows, protecting latency-sensitive traffic on a shared link. ECN marking signals congestion early so that senders reduce their rate before tail drop occurs, which limits queue buildup. A static route can shift flows, but it does not address queue behaviour on the congested link. Raising the MTU does not reduce burst-driven queueing in a meaningful way. Disabling queues removes the mechanisms needed to protect traffic classes.
These are 14 of the 100 questions in the full HPE7-A05 pack.
Get All 100 QuestionsGet all 100 questions & answers
Full access options for HP HPE7-A05
Self-study
PDF Version
- 100 actual exam questions
- Compatible with all devices
- Printable PDF format
- No download limits
- 90 days free updates
- 24/7 customer support
Best value
Bundle Pack
- Discounted PDF + online access
- 100 actual exam questions
- Both PDF and online practice test
- Free 90 days updates
- No download or practice limits
- 24/7 customer support
Exam simulation
Online Practice Test
- 100 actual exam questions
- Actual exam environment
- 90 days free updates
- Browser-based software
- 24/7 customer support
100% Money Back Guarantee
Your success comes first
At DumpsProvider, we give you a 100% money back guarantee on all of our exam dumps. For us, your success is the #1 priority and we are more than confident that our exam material will help you pass the HPE7-A05 Exam (HPE Network Data Center Professional Exam) on your very first attempt.
In a rare case, if you fail your exam, we will refund your amount without asking a single question.