Exam Information
Free practice questions with explanations
VMware 5V0-22.23 Practice Questions
Answer a question to see the correct answer and the explanation, or click Show answer. Newest questions first.
- Questions
- 18
- Answered
- 0
- Correct
- 0
- Score
- -
-
1 Question 1 Single choice Architecture and Technologies
A company is deploying a new vSAN cluster with four hosts across two racks. The security team requires that the cluster tolerate the failure of an entire rack without data loss, and the budget does not allow additional hosts beyond the four already purchased. The architect plans to configure fault domains so each rack is one fault domain. Which storage policy setting best meets the requirement while preserving the most usable capacity within the four-host constraint?
Correct Answer: BExplanationRAID-5 erasure coding with FTT=1 requires a minimum of four fault domains or hosts in a vSAN cluster and provides better capacity efficiency than mirroring, while still surviving the loss of one rack when each rack is a fault domain. Mirroring with FTT=1 consumes twice the raw capacity, which conflicts with the goal of preserving usable capacity. RAID-6 with FTT=2 requires at least six fault domains, so it cannot be satisfied with two racks and four hosts. Adding an object space reservation does not change fault tolerance and only reduces free space.
-
2 Question 2 Single choice Administrative and Operational Task
An operations team runs a vSAN cluster in which all virtual machines use a storage policy with RAID-1 mirroring and FTT=1. A host must undergo a firmware update that requires a reboot, and the expected maintenance window is 25 minutes. The team wants to keep data protected throughout and avoid a full resync after the host returns. Which maintenance mode option should they select?
Correct Answer: AExplanationEnsure accessibility keeps all objects accessible by moving or accepting data as needed while the host is offline, and it avoids the large data movement required by full data migration. For a short 25-minute reboot, it is the recommended choice because the host returns quickly and the resync is limited to changed components. No data migration leaves the host's components unavailable and reduces protection to the remaining replicas during the window. The option mentioning a dedicated spare capacity reservation is not a vSAN maintenance mode option.
-
3 Question 3 Single choice Installing, Configuring, and Setup
An administrator is configuring a vSAN 2-node cluster at a remote branch with a witness appliance hosted in a central data center. The witness link has a 50 Mbps bandwidth and 120 ms latency. The administrator plans to deploy the witness as a virtual appliance and must choose the correct witness size for a deployment expected to hold roughly 300 virtual machines and about 15 TB of data. Which witness appliance size should be selected?
Correct Answer: DExplanationThe witness appliance size must match the number of components and virtual machines in the 2-node cluster. A Large witness supports up to around 500 virtual machines and larger component counts, making it appropriate for roughly 300 virtual machines in a 2-node deployment. Tiny and Normal sizes are sized for far smaller environments and would run out of component capacity. Extra large is oversized for this workload and wastes resources without being required. The witness network characteristics affect latency tolerance, but size is determined by component scale.
-
4 Question 4 Single choice Performance-tuning, Optimization, and Upgrades
A vSAN cluster with ESA enabled on four hosts is being upgraded using vSphere Lifecycle Manager with a desired image. The cluster administrator needs to confirm that the hardware on each host is compatible with the target ESXi release and driver stack before remediation begins. The company's change process requires the check to be done against the official hardware list rather than the local host inventory alone. Which tool should the administrator use to validate compatibility before remediation?
Correct Answer: BExplanationThe vSAN Compatibility Guide is the authoritative source for supported hardware, drivers, and firmware for a given vSAN and ESXi release, and it is the reference the change process requires. Skyline Health reports on the current state of the cluster, including whether the installed components are on the hardware list, but it reflects the local configuration rather than the official list itself. vsantop displays performance metrics and does not validate compatibility. Hardware Health Monitoring reports the condition of physical components rather than supported versions.
-
5 Question 5 Single choice Troubleshooting and Repairing
A vSAN cluster reports a Skyline Health warning that several virtual machine objects are non-compliant with their assigned storage policy. The cluster has 6 hosts, and the policy requires FTT=2 with RAID-6. Two hosts were recently removed for hardware repair, and the remaining hosts have ample free capacity. The administrator has verified that the affected objects are still accessible. Which action is the best NEXT step to resolve the compliance issue?
Correct Answer: CExplanationRAID-6 with FTT=2 requires at least six hosts, and with only four hosts remaining the objects cannot be placed compliantly, so the correct remedy is to restore the host count so the policy can be satisfied and resynchronization can complete. Lowering the policy to FTT=1 changes the protection level without business approval and does not fix the root cause. Recreating virtual machines is disruptive and unnecessary when objects are accessible. Disabling checksum has no bearing on policy compliance and reduces data integrity protection.
-
6 Question 6 Multiple choice Planning and Designing
A healthcare provider is designing a vSAN stretched cluster across two sites connected by a 10 Gbps link with 4 ms round-trip latency. Several databases must remain available if one site fails, and the design must include a witness at a third site. The architect wants to confirm which design statements are correct for the stretched cluster. (Choose two.)
Correct Answer: A, DExplanationThe witness in a stretched cluster must be at a third site and is limited to a round-trip latency of 200 ms to the data sites, so option A is correct. A stretched cluster uses a site disaster tolerance policy that mirrors data across the two sites, combined with local protection such as RAID-1 or RAID-5 within each site, which matches option C. Option B is wrong because data sites do not need two hosts each for site-level protection as a requirement stated in this way. Option D is wrong because the data sites do not require a stretched layer 2 network for vSAN traffic in the modern design. Option E is wrong because ESA is not required for stretched clusters.
-
7 Question 7 Multiple choice Administrative and Operational Task
A cloud operations team manages a vSAN cluster where the number of pending resync objects grew sharply after a host failure. Management wants to understand which capacity and performance statements apply so they can plan the next steps. The team has observed that free capacity shown in the vSAN capacity view differs from the sum of VM disk sizes. Which two statements are accurate? (Choose two.)
Correct Answer: C, DExplanationvSAN capacity views report raw and usable capacity after storage policy overhead, so mirroring and erasure coding reduce what is shown as usable, which makes option A accurate. Resynchronization traffic shares the same backend bandwidth as application I/O, so latency can rise during rebuilds, matching option C. Option B is wrong because thin provisioning does not map directly to free capacity counts. Option D is wrong because space efficiency savings appear at the datastore level, not in disk sizes. Option E is wrong because resync requires capacity that is reflected in the free space accounting.
-
8 Question 8 Order list Installing, Configuring, and Setup
An administrator is preparing to enable vSAN on a new three-host cluster that will host production workloads. The hosts have been installed with ESXi and have been added to a vCenter Server cluster. Arrange the steps in the correct order the administrator must perform to configure vSAN and validate the deployment.
Drag the steps into the correct order, or use the arrows.
- Create a vSAN datastore storage policy and assign it as the default for the cluster
- Run the vSAN health checks in Skyline Health to confirm the cluster is ready for workloads
- Verify that each host has a claimed cache or capacity device eligible for vSAN
- Enable vSAN on the cluster and select the desired configuration such as single-site or ESA
Correct Answer:- Enable vSAN on the cluster and select the desired configuration such as single-site or ESA
- Verify that each host has a claimed cache or capacity device eligible for vSAN
- Create a vSAN datastore storage policy and assign it as the default for the cluster
- Run the vSAN health checks in Skyline Health to confirm the cluster is ready for workloads
ExplanationvSAN must first be enabled on the cluster so the datastore and disk-claiming process can begin. Devices are then verified as eligible and claimed, since claiming requires the vSAN service to be active. A storage policy is created and set as default once the datastore exists, and finally Skyline Health is run to validate the full configuration. Running health checks before enabling vSAN would produce no meaningful results, and assigning policies before devices are claimed has no datastore to apply them to.
-
9 Question 9 Order list Performance-tuning, Optimization, and Upgrades
A vSAN cluster is being expanded with a new host that must be added with its disk group in place and not yet contributing capacity. The administrator must keep the cluster compliant with the current vSphere Lifecycle Manager image during the process. Arrange the steps in the correct order the administrator must perform to add the host safely.
Drag the steps into the correct order, or use the arrows.
- Verify that the new host's devices are eligible for vSAN disk group creation
- Create the disk group on the new host so it contributes capacity to the vSAN datastore
- Add the host to the vCenter cluster and wait for the host to appear in the inventory
- Run Skyline Health and confirm no warnings remain before placing workloads on the host
- Confirm the new host runs the same ESXi image as the cluster desired image
Correct Answer:- Confirm the new host runs the same ESXi image as the cluster desired image
- Add the host to the vCenter cluster and wait for the host to appear in the inventory
- Verify that the new host's devices are eligible for vSAN disk group creation
- Create the disk group on the new host so it contributes capacity to the vSAN datastore
- Run Skyline Health and confirm no warnings remain before placing workloads on the host
ExplanationThe host must first match the cluster desired image so that it does not break image compliance when it joins, which is why image confirmation comes before adding it to the cluster. After the host joins the inventory, devices are checked for eligibility before any disk group is built. The disk group is then created to contribute capacity, and Skyline Health validation is performed last to confirm the expansion is healthy before workloads are placed. Creating the disk group before adding the host to the cluster is not possible because the host must first be part of the cluster inventory.
-
10 Question 10 Drag and drop Architecture and Technologies
A team is documenting the vSAN requirements for three different deployments: a standard cluster with four hosts, a 2-node cluster at a remote office with a witness host, and a stretched cluster spanning two data centers. Match each deployment to the architectural requirement that defines it.
Drag each item onto its matching target. On a phone: tap an item, then tap a target.
Stretched cluster across two data centers2-node cluster at a remote officeStandard cluster with four hosts for a single siteA third site witness with round-trip latency within the supported limitDedicated vSAN cluster with a hardware accelerator for encryption at restA witness appliance hosted outside the two data nodesMinimum of three hosts with capacity devices in each hostA single site with shared external storage for all dataCorrect Answer:- Standard cluster with four hosts for a single site → Minimum of three hosts with capacity devices in each host
- 2-node cluster at a remote office → A witness appliance hosted outside the two data nodes
- Stretched cluster across two data centers → A third site witness with round-trip latency within the supported limit
ExplanationA standard vSAN cluster needs at least three hosts with capacity devices so that protection policies can be placed across failure domains. A 2-node cluster relies on a witness appliance outside the two data nodes to break ties when a node fails. A stretched cluster requires a third site witness whose round-trip latency to the data sites stays within the supported limit. The two extra targets describe encryption hardware and external shared storage, neither of which is a defining architectural requirement of these three topologies.
-
11 Question 11 Drag and drop Products and Solutions
An enterprise is planning integration of vSAN with other VMware products across its environment. Each requirement must be matched to the VMware solution that fulfils it with vSAN. Match each requirement to the solution that meets it.
Drag each item onto its matching target. On a phone: tap an item, then tap a target.
Provide lifecycle image management for hosts in the vSAN clusterProvide Kubernetes persistent volumes backed by vSAN datastoresAllow a remote vSphere cluster to consume storage from an existing vSAN clustervSphere Container Storage Plug-invSphere ReplicationHCI MeshvSphere Lifecycle ManagerSite Recovery ManagerCorrect Answer:- Allow a remote vSphere cluster to consume storage from an existing vSAN cluster → HCI Mesh
- Provide Kubernetes persistent volumes backed by vSAN datastores → vSphere Container Storage Plug-in
- Provide lifecycle image management for hosts in the vSAN cluster → vSphere Lifecycle Manager
ExplanationHCI Mesh allows a remote vSphere cluster to mount vSAN datastores from another cluster, which is the purpose of the first pairing. The vSphere Container Storage Plug-in provisions persistent volumes for Kubernetes workloads on vSAN. vSphere Lifecycle Manager handles image and patch management for the hosts in the cluster. Site Recovery Manager and vSphere Replication address disaster recovery and replication rather than the requirements listed here, so they serve as valid distractors.
-
12 Question 12 Dropdown Installing, Configuring, and Setup
A storage administrator needs to create a storage policy for a set of production databases that must survive two simultaneous host failures and use RAID-6 erasure coding to conserve capacity. The administrator is preparing the policy definition on a cluster with at least six hosts. Select the correct value for each blank in the policy specification.
Choose the correct value for each blank.
Failures to tolerate: Data protection method: Erasure coding:Correct Answer:Failures to tolerate: 2 Data protection method: RAID-6 Erasure coding: Enabled
ExplanationSurviving two simultaneous host failures requires an FTT value of 2, and RAID-6 erasure coding is the corresponding protection method. RAID-6 is only available with FTT=2 and requires at least six hosts, which the cluster provides. Erasure coding must be enabled for RAID-6 to apply to the policy. RAID-1 and RAID-5 do not provide the two-failure tolerance required, and RAID-0 offers no protection at all. Checksum is a separate integrity setting rather than the erasure coding selector.
-
13 Question 13 Dropdown Troubleshooting and Repairing
A vSAN administrator wants to check the health of a cluster from the command line on an ESXi host and review the object health summary. The administrator must run the correct ESXCLI namespace to display vSAN cluster status information. Select the correct value for each blank in the command configuration.
Choose the correct value for each blank.
esxcli cluster Output includes the status of the local host in the vSAN cluster.Correct Answer:esxcli vsan cluster get Output includes the status of the local host in the vSAN cluster.
ExplanationThe ESXCLI vsan namespace is the correct entry point for querying vSAN cluster state on a host, and esxcli vsan cluster get reports membership and status for the local host. The storage namespace covers general storage devices rather than vSAN cluster state, while hardware and network do not expose vSAN membership. The list verb returns different output without the full status detail, and create and remove would change configuration rather than read it.
-
14 Question 14 Single choice Administrative and Operational Task
A company runs a vSAN ESA cluster that stores several virtual machines running a database engine. The DBA reports that deleted rows are not reclaiming space on the datastore, and the storage team needs the guest file deletions to be passed down to the vSAN layer so unused blocks are freed. The company's policy prohibits powering off the virtual machines to make changes. Which configuration meets the requirement with the least disruption?
Correct Answer: CExplanationTRIM and UNMAP pass guest-level block deallocation down through the virtual disk to vSAN, which frees the underlying capacity, and this can be configured without powering off the database VM when the disk supports unmap. Migrating to an external array is unnecessary and violates the stated constraint of keeping data on the vSAN cluster. Increasing object space reservation reserves more space rather than freeing it. Disabling deduplication and compression does not cause reclamation and would reduce space efficiency.
-
15 Question 15 Single choice Troubleshooting and Repairing
A vSAN cluster experiences a disk failure on one capacity device in a disk group. Skyline Health shows the device as failed and reports that several objects are now in a degraded state while the resync is in progress. The operations team wants to determine how the failure affects the virtual machines and whether any data is at risk right now. Which assessment is correct?
Correct Answer: DExplanationWhen a capacity device fails, vSAN keeps objects accessible as long as the storage policy's failures-to-tolerate level provides surviving replicas or parity, but the objects temporarily run with reduced redundancy until components are rebuilt elsewhere. Full inaccessibility would only occur if more failures than the policy tolerates existed. Immediate permanent loss is incorrect because redundant copies are used for recovery. The cache tier does not hold a complete copy of all data, so the claim about it is wrong.
-
16 Question 16 Single choice Planning and Designing
An architect designs a vSAN cluster for a financial services firm that requires data at rest to be encrypted, and the firm wants to use key management managed by its existing KMS. The architect proposes vSAN data-at-rest encryption, but the design team asks whether data-in-transit encryption must also be considered for the replication traffic between hosts. The firm's security baseline requires encryption on all vSAN network traffic between hosts. Which conclusion is correct about the encryption design?
Correct Answer: CExplanationvSAN data-at-rest encryption protects stored data, while data-in-transit encryption is a separate setting that encrypts traffic between hosts, and the security baseline requires both. Enabling the KMS for data-at-rest does not encrypt the network path on its own, so option A is wrong. A KMS is required for encryption at rest, but this does not prevent the baseline from being satisfied, so option C is wrong. Data-in-transit encryption is not enabled by default in ESA clusters, so option D is wrong.
-
17 Question 17 Multiple choice Administrative and Operational Task
A vSAN cluster administrator must interpret capacity and performance data for a monthly review. The cluster is experiencing higher than expected latency during business hours, and the storage team wants to decide which observations justify deeper investigation before adding capacity. Which two observations are the most valid reasons for further investigation? (Choose two.)
Correct Answer: B, DExplanationSustained write latency that rises with congestion on the capacity tier is a direct performance warning sign that warrants investigation, which matches option A. A VM with a provisioned disk far larger than its written data is a capacity planning signal that can indicate over-provisioning, which matches option B. Free capacity above the recommended slack space threshold and stable read cache hit rates are healthy indicators that do not require investigation. Resync completing within the expected window after planned maintenance is normal behaviour.
-
18 Question 18 Single choice Installing, Configuring, and Setup
A team is configuring an HCI Mesh deployment in which a compute-only cluster needs access to datastores provided by a vSAN cluster in a separate environment. The compute-only cluster runs ESXi hosts managed by the same vCenter Server. The team plans to mount the remote vSAN datastore on the compute-only cluster. Which requirement must be satisfied for the mount to succeed?
Correct Answer: DExplanationHCI Mesh mounts a remote vSAN datastore on compute-only hosts, and this requires that those hosts can communicate with the vSAN cluster over the vSAN network so the remote datastore can be accessed. The compute-only cluster does not need local disk groups because it contributes compute resources only, which makes option A wrong. Mixing ESA and OSA between the two clusters is not a requirement, so option C is wrong. A stretched topology is not required for HCI Mesh, so option D is wrong.
These are 18 of the 75 questions in the full 5V0-22.23 pack.
Get All 75 QuestionsGet all 75 questions & answers
Full access options for VMware 5V0-22.23
Self-study
PDF Version
- 75 actual exam questions
- Compatible with all devices
- Printable PDF format
- No download limits
- 90 days free updates
- 24/7 customer support
Best value
Bundle Pack
- Discounted PDF + online access
- 75 actual exam questions
- Both PDF and online practice test
- Free 90 days updates
- No download or practice limits
- 24/7 customer support
Exam simulation
Online Practice Test
- 75 actual exam questions
- Actual exam environment
- 90 days free updates
- Browser-based software
- 24/7 customer support
100% Money Back Guarantee
Your success comes first
At DumpsProvider, we give you a 100% money back guarantee on all of our exam dumps. For us, your success is the #1 priority and we are more than confident that our exam material will help you pass the 5V0-22.23 Exam (VMware vSAN Specialist v2) on your very first attempt.
In a rare case, if you fail your exam, we will refund your amount without asking a single question.