Exam Information
Free practice questions with explanations
NetApp NS0-522 Practice Questions
Answer a question to see the correct answer and the explanation, or click Show answer. Newest questions first.
- Questions
- 14
- Answered
- 0
- Correct
- 0
- Score
- -
-
1 Question 1 Single choice ONTAP SAN Concepts
A healthcare provider runs an Oracle database on an ONTAP 9.x SAN cluster using FC LUNs. The compliance team requires that accidental deletion of a LUN can be recovered for 7 days without consuming a full copy of the data, and the storage team wants the recovery to be possible from the same cluster without restoring from backup media. Snapshot copies are already scheduled hourly on the volume. Which action best meets these requirements?
Correct Answer: DExplanationSnapshot copies in ONTAP are point-in-time, space-efficient pointers to blocks, so keeping hourly copies for seven days provides recovery of a deleted LUN on the same cluster without a full data copy. Replication to a secondary cluster adds cost and does not satisfy the same-cluster requirement. FlexClone volumes create writable copies that consume space as they diverge and are not a retention mechanism for recovery. SnapVault is a long-term backup relationship that requires a secondary destination, which the requirement does not call for.
-
2 Question 2 Single choice ONTAP SAN Concepts
A retail company is deploying a two-node ONTAP cluster for an iSCSI-based point-of-sale database. The storage administrator is asked to explain how the host should reach its LUNs during a planned takeover of one node in an HA pair. The LUNs must remain accessible without the host having to be reconfigured, and the design must avoid single points of failure in the front-end network. Which configuration principle satisfies this?
Correct Answer: DExplanationONTAP SAN uses ALUA to advertise optimized paths through the node that currently owns the LUN and non-optimized paths through its HA partner, and the host's multipathing software uses this to fail over without reconfiguration. Restricting access to a single fixed path creates a single point of failure. Limiting the igroup to one initiator port removes redundancy on the host side. Disabling ALUA removes the path priority information the host needs during a takeover, which degrades rather than protects availability.
-
3 Question 3 Single choice ONTAP SAN implementation and configuration
A manufacturing firm is adding a new ONTAP 9.x cluster with two nodes to replace an aging system. The cluster has two nodes with a cluster interconnect and both nodes are already joined to a cluster. The implementation engineer must create an SVM dedicated to block workloads that will serve FCP LUNs to hosts on two separate fabrics. Which step should be performed first when building the SVM for FC access?
Correct Answer: DExplanationAn SVM must exist and have the FCP protocol enabled before FC LIFs and LUN mapping can be configured on it, so creating the SVM and enabling FCP is the foundational first step. Creating LIFs before the SVM has FCP enabled is not a valid sequence in the workflow. igroups are created on the storage side using host WWPNs, not on the host, and cannot target port WWPNs before the storage configuration exists. LUNs cannot be created or mapped outside an SVM and volume context.
-
4 Question 4 Single choice ONTAP SAN implementation and configuration
A logistics company runs a clustered ONTAP system that hosts an SVM for iSCSI block storage. The company wants a dedicated iSCSI LIF for the SVM placed on a subnet separate from its management network and a VLAN-tagged network segment, so that storage traffic is isolated. The network team reports that they already have an IP subnet assignment for the storage VLAN in another SVM. Which action best meets the requirement while avoiding a conflict with the existing configuration?
Correct Answer: CExplanationIn ONTAP, IPspaces provide separate routing and address domains so that overlapping IP ranges used by different SVMs do not conflict, and a broadcast domain within the IPspace holds the VLAN-tagged ports used for LIFs. Reusing the management broadcast domain would mix storage and management traffic and does not isolate the subnet. Placing the storage VLAN in the cluster IPspace is inappropriate because cluster traffic is reserved for intra-cluster communication. Switch ACLs do not change the ONTAP addressing model and do not meet the requirement for separate routing in ONTAP.
-
5 Question 5 Single choice ONTAP SAN implementation and configuration
An NVMe/FC deployment is being built for an analytics platform on an ONTAP 9.x cluster. The hosts run an operating system with a supported NVMe/FC initiator and will connect through two FC switches in a dual-fabric design. The team has created the NVMe namespaces and the NVMe subsystem but the hosts cannot see the namespaces. The fabric shows the initiator ports logged in. What is the most likely configuration gap?
Correct Answer: DExplanationWith ONTAP NVMe, host access is controlled by the NVMe subsystem, where host NQNs are added and namespaces are mapped to the subsystem; logged-in initiators with no subsystem membership see no namespaces. Creating the storage as iSCSI LUNs would be a different object type, and the premise of NVMe namespaces already exists in the scenario. NVMe/FC uses WWPN-based zoning like standard FC, so the port-number explanation is wrong. NVMe/FC does not depend on the iSCSI service on the SVM.
-
6 Question 6 Single choice ONTAP SAN implementation and configuration
A university is migrating a Windows Server Hyper-V cluster with a mix of FC and iSCSI LUNs onto an ONTAP system. The storage administrator must provide a host-side configuration that prevents data corruption when a LUN is presented to two Hyper-V nodes. The ONTAP side is already configured with igroups for each host. Which host-level configuration requirement must be verified for ONTAP SAN LUN access in this design?
Correct Answer: CExplanationFor ONTAP SAN, the host utilities kit and the correct host type on each igroup/LUN mapping ensure that the host receives the right SCSI settings and multipathing behaviour, which is the basis for safe shared access in a clustered environment. Setting space reservation to none does not address shared access and risks running out of space. Mapping all nodes through a single initiator port removes redundancy, and deduplication has no bearing on write serialisation between hosts.
-
7 Question 7 Single choice ONTAP SAN implementation testing and troubleshooting
A bank's ONTAP cluster serves FC LUNs to a database. After a planned maintenance window in which a fibre channel switch was replaced, the database team reports intermittent I/O timeouts. The storage administrator checks the host and sees that only two of the four expected paths to each LUN are active. The FC switch is now the same model and firmware as the failed unit. The ports on the new switch are cabled correctly. Which action is the most appropriate next step?
Correct Answer: CExplanationWhen paths are missing after a switch replacement, the most likely cause is zoning that does not include all initiator and target WWPN pairs, so verifying zones and checking which initiator ports have logged into the ONTAP FC targets identifies the gap. Increasing queue depth does not restore missing paths. Remapping to only the two active paths would reduce redundancy and fix nothing. Rebooting the nodes is disruptive to a production database and is not the first diagnostic step.
-
8 Question 8 Single choice ONTAP SAN implementation testing and troubleshooting
A company performs a planned migration of a SQL Server database from an older storage array to ONTAP using a LUN import with a one-hour cutover window. After the cutover, the application team reports that the database cannot mount because the LUN's partition signature does not match the expected mounted disk. The new LUN is mapped correctly and the host sees the device. The team needs to restore service within the cutover window. Which action is most appropriate?
Correct Answer: CExplanationA signature or identifier mismatch after migration usually means the host is looking at a LUN with different geometry or host-type settings than the source, so verifying the host type, the size, and the disk identifiers on the migrated LUN is the quickest path to a working mount inside the window. Recreating the database from backup would blow the cutover window. Thin provisioning is a space setting with no effect on partition signatures. Recreating the igroup does not alter the disk identity the host sees.
-
9 Question 9 Single choice ONTAP SAN implementation testing and troubleshooting
During acceptance testing of a new iSCSI SAN, a test engineer simulates the failure of one storage node in an HA pair while a host performs sustained writes. The test shows that writes continue after a pause, but the host's error log records that the path to the LUN was in a non-optimized state for the duration. The customer requires that the test confirm the LUN continues to be served by an optimized path after failover. Which action best validates this requirement?
Correct Answer: CExplanationAfter giveback in an ONTAP HA configuration, LUN ownership returns to the original node and optimized paths should be reinstated on the host, which can be verified through the host multipath status and LUN ownership. Comparing throughput does not confirm path state. Disabling ALUA would hide the very behaviour the test must validate. Increasing LUN size has no effect on path state.
-
10 Question 10 Single choice ONTAP SAN implementation testing and troubleshooting
An enterprise customer uses SnapMirror to replicate a LUN volume from a primary ONTAP cluster to a disaster recovery cluster. During a test failover, the DR site's host is able to read the replicated LUN but writes fail with an error indicating the destination is read-only. The team has already broken the SnapMirror relationship. Which step is the most appropriate next action to make the DR LUN writable?
Correct Answer: AExplanationBreaking a SnapMirror relationship converts the destination into a writable volume, but the LUN must still be mapped to the appropriate igroup on the DR cluster before the host can write, so confirming both is the right next step. Resynchronising in reverse would re-establish protection and make the destination read-only again. Deleting and recreating the LUN from the primary would require data transfer and discards the replicated state. Converting to FlexGroup is not a valid fix for a read-only destination.
-
11 Question 11 Single choice ONTAP SAN implementation testing and troubleshooting
A telecom operator is planning to move 40 LUNs from an older array to an ONTAP cluster using ONTAP-supported data migration tooling. The migration must avoid extended downtime, and the operator has a strict rule that the source LUNs must remain untouched and intact until the target has been validated. Which migration approach best satisfies these constraints?
Correct Answer: AExplanationA copy-based transition leaves the source LUNs intact while data is copied to ONTAP, and cutover happens per host after validation, which keeps downtime short and meets the rule that sources are untouched. Detaching and exporting the sources risks changing them and extends downtime. Reformatting and restoring from tape is slow and cannot meet the window. A single offline cutover for all LUNs maximises downtime and does not satisfy the phased validation approach.
-
12 Question 12 Multiple choice ONTAP SAN solution assessment
A regional hospital network plans to deploy an ONTAP SAN solution for clinical databases and a VMware vSphere environment. The design must support two data centers, a 1 ms round-trip latency budget between the primary and secondary sites, and no single point of failure on the host-to-array path. The team must complete the planning inventory before purchasing. Which TWO actions should be completed during the planning phase to satisfy these requirements? (Choose two.)
Correct Answer: B, EExplanationValidating host HBA, firmware, and operating system versions against the Interoperability Matrix Tool is a planning prerequisite that prevents unsupported configurations and rework. Measuring inter-site latency confirms whether synchronous replication can meet the 1 ms budget before the architecture is committed. Assuming switch compatibility skips a required check, a single switch per fabric creates a single point of failure, and deferring environmental planning ignores power and cooling constraints that affect rack design.
-
13 Question 13 Multiple choice ONTAP SAN solution assessment
A financial services firm is designing an ONTAP SAN solution for an in-memory trading platform that requires sub-millisecond latency and 99.999 percent availability. The firm has a limited budget and wants to avoid buying capacity it will not use. Which TWO design choices best meet these requirements while keeping cost under control? (Choose two.)
Correct Answer: B, EExplanationNVMe over FC gives the trading hosts a low-latency protocol path, and a two-node HA pair with dual-fabric redundancy removes single points of failure in both the controller and the connectivity layers. Provisioning far beyond the 80 TB dataset ties up budget unnecessarily, and 1 Gbps iSCSI cannot meet sub-millisecond performance goals. Enabling efficiency features does not replace capacity planning, since savings depend on the data.
-
14 Question 14 Multiple choice ONTAP SAN solution assessment
A manufacturing company plans to refresh its SAN with ONTAP and must confirm the environmental and physical requirements before shipment. The new cluster will be installed in an existing rack that is shared with legacy servers, and the data hall has a power budget limit. Which TWO planning actions should be performed to avoid installation delays and operating risk? (Choose two.)
Correct Answer: A, EExplanationConfirming power draw, heat output, and cooling capacity against the rack and data hall budget is a core environmental assessment step that prevents overheating and overloaded circuits. Checking depth, weight rating, and rail compatibility ensures the chassis physically fits the rack. Assuming size compatibility from a comparison with legacy servers is unreliable, removing blanking panels disrupts the airflow design, and ignoring cabling undermines serviceability and airflow.
These are 14 of the 107 questions in the full NS0-522 pack.
Get All 107 QuestionsGet all 107 questions & answers
Full access options for NetApp NS0-522
Self-study
PDF Version
- 107 actual exam questions
- Compatible with all devices
- Printable PDF format
- No download limits
- 90 days free updates
- 24/7 customer support
Best value
Bundle Pack
- Discounted PDF + online access
- 107 actual exam questions
- Both PDF and online practice test
- Free 90 days updates
- No download or practice limits
- 24/7 customer support
Exam simulation
Online Practice Test
- 107 actual exam questions
- Actual exam environment
- 90 days free updates
- Browser-based software
- 24/7 customer support
100% Money Back Guarantee
Your success comes first
At DumpsProvider, we give you a 100% money back guarantee on all of our exam dumps. For us, your success is the #1 priority and we are more than confident that our exam material will help you pass the NS0-522 Exam (NetApp Implementation Engineer - SAN ONTAP) on your very first attempt.
In a rare case, if you fail your exam, we will refund your amount without asking a single question.