Exam Information
Free practice questions with explanations
NetApp NS0-175 Practice Questions
Answer a question to see the correct answer and the explanation, or click Show answer. Newest questions first.
- Questions
- 15
- Answered
- 0
- Correct
- 0
- Score
- -
-
1 Question 1 Single choice FlexPod Design
A healthcare provider is designing a FlexPod Datacenter solution with NetApp AFF storage and Cisco UCS. The design must support a 40 Gbps uplink from the UCS fabric interconnects to the Nexus switches and must keep storage traffic isolated from management traffic. A design reviewer proposes using a single VLAN for NFS storage traffic across both fabrics and placing the storage data LIFs on the same subnet as the management network to simplify routing. The compliance team requires separate paths for storage and management for audit purposes, and the budget excludes additional fabric interconnects. Which design change BEST meets the requirements?
Correct Answer: CExplanationSeparating storage data LIFs onto their own VLAN and subnet, with dedicated vNICs mapped to each fabric, gives the isolation the compliance team needs without new hardware. Logical separation at the VLAN and vNIC level is what FlexPod design uses to keep storage and management paths distinct. Adding a second fabric interconnect pair breaks the budget constraint. Keeping one storage VLAN with a management VLAN on the same vPC still shares the uplink path, so it fails the separation requirement. Relying on QoS on a single vNIC prioritises traffic but does not isolate it for audit purposes.
-
2 Question 2 Order list FlexPod Configuration
A team is configuring SAN boot for a new Cisco UCS blade running ESXi against a NetApp ONTAP SVM. The boot LUN must be presented only to this server's initiators, and the service profile must reference the boot policy correctly before the first boot. Arrange the steps in the correct order.
Drag the steps into the correct order, or use the arrows.
- Create a SAN boot policy in UCS Manager pointing to the target WWPNs
- Map the boot LUN to the igroup using a specific LUN ID
- Associate the boot policy with the service profile and power on the server
- Create the igroup on the SVM containing the server's vHBA WWPNs
- Create the boot LUN on the SVM volume and size it for the ESXi image
Correct Answer:- Create the igroup on the SVM containing the server's vHBA WWPNs
- Create the boot LUN on the SVM volume and size it for the ESXi image
- Map the boot LUN to the igroup using a specific LUN ID
- Create a SAN boot policy in UCS Manager pointing to the target WWPNs
- Associate the boot policy with the service profile and power on the server
ExplanationThe LUN must exist before it can be mapped, and the igroup must hold the initiator WWPNs before the mapping is created so that only this server sees the boot device. The UCS boot policy referencing target WWPNs is built before it is attached to the service profile, and the server is powered on only after association. Creating the boot policy before the LUN exists is unnecessary here because the target WWPNs come from the SVM LIFs, which the boot policy needs but which are independent of the LUN itself, so the boot policy step is placed after the mapping in a way that still keeps the storage side ready before the host is started.
-
3 Question 3 Drag and drop FlexPod Administration
A FlexPod operations team manages a Cisco UCS domain, NetApp ONTAP clusters, and Nexus switches for a regional hospital network. They need each task to be performed with the management application best suited to it. Match each requirement to the management tool that meets it.
Drag each item onto its matching target. On a phone: tap an item, then tap a target.
Automate ONTAP configuration changes through repeatable playbooksMonitor storage capacity and performance trends across ONTAP clusters from one dashboardManage UCS server identity, firmware policies, and service profilesCisco UCS ManagerNetApp SnapCenter backup policiesNetApp Active IQ Unified ManagerAnsible modules for ONTAPCisco Data Center Network Manager fabric viewsCorrect Answer:- Monitor storage capacity and performance trends across ONTAP clusters from one dashboard → NetApp Active IQ Unified Manager
- Manage UCS server identity, firmware policies, and service profiles → Cisco UCS Manager
- Automate ONTAP configuration changes through repeatable playbooks → Ansible modules for ONTAP
ExplanationActive IQ Unified Manager provides ONTAP cluster health, capacity, and performance monitoring, while UCS Manager is the native tool for service profiles, identity pools, and firmware policies in a UCS domain. Ansible modules for ONTAP are the supported route for scripted, repeatable ONTAP configuration. Cisco DCNM manages Nexus fabric views rather than server identity, and SnapCenter handles application-consistent backup policies, so neither matches the requirements listed.
-
4 Question 4 Single choice FlexPod Troubleshooting
After a firmware upgrade on a Cisco UCS domain in a FlexPod deployment, one blade running ESXi loses connectivity to its datastore on NetApp ONTAP. The datastore is accessed over iSCSI through vNICs on both fabrics. The host shows active paths on Fabric A only. Fabric interconnect B reports the vNIC as up, and the ONTAP LIFs are online on both nodes. The engineer must restore multipath access with the least disruption to other workloads. Which action should be taken FIRST?
Correct Answer: DExplanationThe LIFs are online on both nodes and the Fabric B vNIC reports up, so the likely fault is configuration on that path, such as a VLAN or MTU mismatch in the service profile after the upgrade. Checking that vNIC settings first is the least disruptive step. Rebooting the blade is disruptive and may not change the vNIC configuration. Failing over LIFs addresses a problem that the status output does not show. Disabling Fabric A removes the working path and would worsen the outage.
-
5 Question 5 Multiple choice FlexPod Design
A financial services firm is sizing a FlexPod Datacenter deployment that must support a mixed workload of virtualised databases and VDI with strict latency targets. The firm wants a design that uses Cisco UCS and NetApp AFF systems and remains within a standard Cisco UCS fabric topology. Which TWO components or design choices are appropriate for the compute and networking layers? (Choose two.)
Correct Answer: B, DExplanationUCS B-Series blades attached to 6400 Series fabric interconnects are a standard supported compute and fabric combination in FlexPod Datacenter, and Nexus 9000 Series switches are a supported upstream networking layer. Managing C-Series servers without fabric interconnects breaks the stated unified UCS management model used in the design. The Nexus 1000V is not required for ESXi hosts in current FlexPod designs. E-Series is not a supported primary storage platform in FlexPod Datacenter, which uses AFF and FAS systems.
-
6 Question 6 Dropdown FlexPod Configuration
A FlexPod engineer is configuring an ONTAP SVM for NFS datastores that must be exported only to the ESXi management VMkernel subnet 10.10.20.0/24. The export policy must restrict access and the rule must be applied to the volume. Complete the ONTAP CLI command by selecting the correct value for each blank.
Choose the correct value for each blank.
vserver export-policy rule create -vserver svm_fp -policyname -clientmatch 10.10.20.0/24 -rorule sys -rwrule sys -superuser -protocol nfs3Correct Answer:vserver export-policy rule create -vserver svm_fp -policyname esx_nfs -clientmatch 10.10.20.0/24 -rorule sys -rwrule sys -superuser none -protocol nfs3
ExplanationUsing a dedicated export policy such as esx_nfs ensures the rule applies only to the datastore volumes rather than a shared default policy used elsewhere in the SVM. Restricting superuser access to none prevents root on the ESXi clients from acting as root on the NFS export, which is a standard security practice for datastores. Setting superuser to sys would grant root mapping to the trusted client, and any or krb5 do not match the intended restriction. The default policy is shared and should not be modified for a targeted datastore export.
-
7 Question 7 Single choice FlexPod Administration
A FlexPod operator needs to upgrade a Cisco UCS domain's firmware. The domain runs production ESXi hosts that must remain available throughout. The fabric interconnects are in a high-availability cluster, and each blade has vNICs on both fabrics. The change window allows no outage. Which upgrade approach follows FlexPod best practice?
Correct Answer: BExplanationWith the fabric interconnects in a high-availability cluster and vNICs spread across both fabrics, upgrading the subordinate first keeps the primary carrying traffic, and verifying recovery before moving on preserves availability. Upgrading both at once removes all paths and causes an outage. Shutting down blades is unnecessary and violates the no-outage constraint. Manually disabling vNICs on one fabric removes redundancy without benefit, and the fabric interconnect firmware process is designed to be sequenced rather than preceded by disabling connectivity.
-
8 Question 8 Single choice FlexPod Configuration
A cloud provider is building a FlexPod deployment for multi-tenant workloads on NetApp ONTAP and Cisco UCS. Each tenant must have its own storage virtual machine, and the design must prevent one tenant's administrators from viewing or changing another tenant's volumes. The provider wants to delegate day-to-day volume management to each tenant without granting cluster-wide privileges. Which configuration BEST meets this requirement?
Correct Answer: CExplanationEach tenant gets its own SVM, and assigning the vsadmin role scopes administrative rights to that SVM only, so tenants cannot see or modify each other's volumes. Quotas alone do not provide administrative isolation. Granting cluster admin violates the no-cluster-wide-privileges requirement. A shared admin account removes accountability and does not meet the per-tenant delegation goal.
-
9 Question 9 Drag and drop Information Gathering for FlexPod Solutions
A solutions architect is gathering information from a customer before a FlexPod proposal for a manufacturing site. The customer's existing environment includes a mix of hardware that must be documented accurately before design sign-off. Match each piece of information to the FlexPod component it describes.
Drag each item onto its matching target. On a phone: tap an item, then tap a target.
Number of blade slots, adapter type, and firmware bundle in useNumber of nodes in the HA pair and disk shelf inventoryUpstream port-channel configuration and VLAN trunking to the coreCisco Nexus switching layerNetApp SnapMirror relationship inventoryNetApp ONTAP storage clusterVMware vCenter inventory tagsCisco UCS compute domainCorrect Answer:- Number of blade slots, adapter type, and firmware bundle in use → Cisco UCS compute domain
- Number of nodes in the HA pair and disk shelf inventory → NetApp ONTAP storage cluster
- Upstream port-channel configuration and VLAN trunking to the core → Cisco Nexus switching layer
ExplanationBlade slots, adapters, and firmware bundles describe the UCS compute domain, whereas HA pair nodes and shelves describe the ONTAP cluster hardware. Port-channels and VLAN trunks to the core belong to the Nexus switching layer. SnapMirror relationships are replication state rather than hardware inventory, and vCenter tags are virtualisation metadata, so neither matches a component inventory question.
-
10 Question 10 Single choice FlexPod Troubleshooting
An ESXi cluster on a FlexPod system shows intermittent NFS datastore disconnects under load. The NetApp volume is exported over a 10 GbE interface group. The ESXi VMkernel ports use jumbo frames with MTU 9000, but the storage LIFs on ONTAP are configured with MTU 1500 on the same VLAN. Pings with the default size succeed, while large transfers stall. The team wants to fix the root cause with the smallest change. Which action resolves the problem?
Correct Answer: CExplanationDefault-size pings pass while large transfers stall because the MTU mismatch only fails with frames above 1500 bytes, so the ONTAP broadcast domain and the physical port need MTU 9000 to match the hosts. Lowering the host MTU removes the performance benefit of jumbo frames and only moves the mismatch. Changing the timeout masks the symptom rather than the cause. Moving the datastore to a VLAN without jumbo frames still leaves the mismatch on the path and reduces performance.
-
11 Question 11 Order list FlexPod Configuration
A FlexPod engineer must add a new NetApp AFF volume and expose it as an NFS datastore to an ESXi cluster that runs on Cisco UCS. The volume must use an export policy that only the cluster's storage VMkernel subnet can access. Arrange the steps in the correct order.
Drag the steps into the correct order, or use the arrows.
- Verify the datastore is accessible from all hosts and paths are healthy
- Create the volume on the SVM with the required size and junction path
- Create a dedicated export policy on the SVM with rules for the storage subnet
- Mount the NFS export as a datastore on each ESXi host in the cluster
- Assign the export policy to the volume
Correct Answer:- Create the volume on the SVM with the required size and junction path
- Create a dedicated export policy on the SVM with rules for the storage subnet
- Assign the export policy to the volume
- Mount the NFS export as a datastore on each ESXi host in the cluster
- Verify the datastore is accessible from all hosts and paths are healthy
ExplanationThe volume must exist before it can be given a junction path and export policy, and the export policy must exist before it can be assigned to the volume. Mounting the export on the ESXi hosts comes only after the export is accessible, and verification confirms that every host can reach the datastore. Creating the export policy after mounting would leave the datastore either unexported or open to unintended clients.
-
12 Question 12 Single choice FlexPod Administration
A FlexPod administrator is preparing to upgrade the ONTAP software on a two-node AFF cluster that serves production SAN and NAS workloads. The business requires that clients experience no unplanned interruption, and the cluster must keep its non-disruptive operation capability. Before starting, which check is the MOST important to perform first?
Correct Answer: BExplanationRunning the ONTAP upgrade advisor pre-checks against the target release identifies configuration and compatibility issues that could otherwise cause an interruption, which is the decisive first step for a no-disruption requirement. Choosing the newest image without checking compatibility can introduce incompatibility with hosts or features. Disabling SnapMirror is not a required step and risks replication gaps. Shutting down hosts defeats the purpose of a non-disruptive upgrade.
-
13 Question 13 Multiple choice FlexPod Design
A university research group is designing a FlexPod solution to host genomics workloads that need high sequential throughput over NFS, while keeping the storage tier cost-controlled. The design must remain within supported FlexPod storage components. Which TWO storage choices are appropriate? (Choose two.)
Correct Answer: C, DExplanationAn AFF A400 with NFS data LIFs on 100 GbE provides the high sequential throughput required and is a supported FlexPod storage platform, and FAS systems are supported within FlexPod for a lower-cost tier managed in ONTAP. E-Series, a standalone Linux server, and StorageGRID are not appropriate as the primary NFS datastore in a supported FlexPod storage design, since FlexPod storage is delivered through ONTAP systems. The Linux server would also sit outside the managed storage platform.
-
14 Question 14 Dropdown FlexPod Troubleshooting
An administrator is diagnosing a host that cannot see its iSCSI LUN on a FlexPod system after a zoning change. The fabric shows the initiator logged in, but ONTAP reports the initiator is not in the igroup. The administrator needs to confirm the igroup contents from the ONTAP CLI and add the missing initiator. Complete the command by selecting the correct value for each blank.
Choose the correct value for each blank.
lun igroup show -vserver svm_fp -igroup -fieldsCorrect Answer:lun igroup show -vserver svm_fp -igroup ig_esx01 -fields initiator
ExplanationThe igroup named ig_esx01 is the group that should hold this host's initiator, and the field initiator is the one that lists the initiator names registered in the group, which is what needs checking here. Other igroup-related values such as wwpn are not the displayed field name for this listing, lunid belongs to LUN mapping output, and portset is a separate construct. The other igroup names reference boot or datastore objects rather than this host's group.
-
15 Question 15 Single choice FlexPod Configuration
A FlexPod team is configuring the Cisco Nexus switches in a vPC pair that connects to the UCS fabric interconnects and NetApp controllers. The design requires that the vPC domain stays up if one peer link fails and that both switches share state to prevent split-brain. Which configuration element is REQUIRED to achieve this?
Correct Answer: DExplanationA vPC requires a dedicated peer link for synchronising state and a separate peer-keepalive link to detect peer failure without relying on the peer link, which is what prevents split-brain. PortFast on member ports does not provide peer synchronisation, a single port channel carrying all VLANs lacks the keepalive separation, and a static route on management addresses does not define a vPC domain.
These are 15 of the 60 questions in the full NS0-175 pack.
Get All 60 QuestionsGet all 60 questions & answers
Full access options for NetApp NS0-175
Self-study
PDF Version
- 60 actual exam questions
- Compatible with all devices
- Printable PDF format
- No download limits
- 90 days free updates
- 24/7 customer support
Best value
Bundle Pack
- Discounted PDF + online access
- 60 actual exam questions
- Both PDF and online practice test
- Free 90 days updates
- No download or practice limits
- 24/7 customer support
Exam simulation
Online Practice Test
- 60 actual exam questions
- Actual exam environment
- 90 days free updates
- Browser-based software
- 24/7 customer support
100% Money Back Guarantee
Your success comes first
At DumpsProvider, we give you a 100% money back guarantee on all of our exam dumps. For us, your success is the #1 priority and we are more than confident that our exam material will help you pass the NS0-175 Exam (Cisco and NetApp FlexPod Design Specialist) on your very first attempt.
In a rare case, if you fail your exam, we will refund your amount without asking a single question.