2026 Actual Dell D-PSC-MN-01 Dumps, Updated Exam Questions for Guaranteed Pass

Dell PowerScale Maintenance Version 2 - Free Interactive Quiz, Exam Dumps, and Complete Practice Pack from DumpsProvider.

Exam Information

5.0 (175 reviews) Reviewed by DumpsProvider Editorial Team

VendorDell
Exam codeD-PSC-MN-01
Exam nameDell PowerScale Maintenance Version 2
Questions in pack101
Last updatedOctober 23, 2024
Related certificationsPowerScale Maintenance

Free interactive sample

D-PSC-MN-01 Short Quiz

5 Real Exam Questions - One at a Time - Instant or End-of-quiz Scoring.

Study mode
Timer
Passing score
60%

D-PSC-MN-01 free sample questions and answers

Dell D-PSC-MN-01 practice quiz with correct answers for search indexing.

  1. Question 1

    What type of NIC is used for the external network on a Dell EMC PowerScale F600 node?

    Correct answer: C

    The Dell EMC PowerScale F600 node uses 25 Gigabit Ethernet for external networking.

    Details:

    25 GbE NICs:

    Provide high bandwidth suitable for performance-intensive workloads.

    Support modern data center networking standards.

    Dell PowerScale Reference:

    Dell EMC PowerScale F600 Technical Specifications:

    Networking Section:

    Specifies the use of 25 GbE NICs for external connections.

    Best Practices:

    Ensure network infrastructure (switches, cables) supports 25 GbE.

    Configure network settings to optimize performance.


  2. Question 2

    A platform engineer is connecting a new Dell EMC PowerScale F600 node to the back-end switch.

    How should the back-end cable be connected?

    Correct answer: B

    For Dell EMC PowerScale F600 nodes, back-end connectivity is essential for node communication and cluster operations. The F600 uses Ethernet for back-end networking.

    Cabling Instructions:

    PCIe Slot 1 Usage:

    PCIe slot 1 is designated for back-end Ethernet connections in F600 nodes.

    This slot houses the network interface card (NIC) responsible for internal cluster communication.

    Connecting to Back-End Ethernet Switch:

    Cables from PCIe slot 1 should be connected to the back-end Ethernet switch.

    Ensures that nodes can communicate over the internal network.

    Key Points:

    Avoiding InfiniBand Reference:

    F600 nodes use Ethernet, not InfiniBand, for back-end networking.

    Options mentioning InfiniBand switches are incorrect.

    Slot Selection:

    PCIe slot 3 is not used for back-end connections in F600 nodes.

    Correct slot usage is critical for network functionality.

    Dell PowerScale Reference:

    Dell EMC PowerScale Hardware Installation Guide:

    Cabling Diagrams for F600 Nodes illustrate the correct connections from PCIe slot 1.

    Back-End Network Setup section provides detailed instructions.

    Networking Best Practices:

    Use recommended cables and connectors for Ethernet connections.

    Label cables and ports to prevent misconfiguration.


  3. Question 3

    A platform engineer needs to swap an NVDIMM battery. What prerequisite conditions are required to prevent data loss when removing the NVDIMM battery?

    Correct answer: D

    Non-Volatile Dual In-line Memory Modules (NVDIMMs) are used in Dell EMC PowerScale nodes to enhance write performance and data protection. The NVDIMM battery provides backup power to ensure data in the NVDIMM is preserved during a power loss.

    Prerequisite Conditions:

    Complete Power Off:

    The node must be completely powered off.

    All LEDs on the node, NVDIMM, and NVDIMM battery must be off to ensure no power is supplied.

    Prevent Data Loss:

    Removing the NVDIMM battery while power is present can lead to data loss in the NVDIMM.

    Ensuring all LEDs are off confirms that the NVDIMM has flushed its data and is safe to handle.

    Why Other Options Are Incorrect:

    Option A (Hot-Swappable):

    The NVDIMM battery is not hot-swappable.

    Option B (Node Off and Removed from Power Feed):

    While the node should be off, additional confirmation of LEDs being off is necessary.

    Option C (LEDs on NVDIMM Battery Must Be Off):

    Not sufficient; all related LEDs must be off.

    Dell PowerScale Reference:

    Dell EMC PowerScale Hardware Replacement Guide:

    Section on NVDIMM Battery Replacement:

    Specifies that the node and all related LEDs must be off before removing the NVDIMM battery.

    Provides step-by-step procedures to safely replace the battery.

    Safety Precautions:

    Wear ESD protection when handling internal components.

    Verify power status to prevent hardware damage and data loss.


  4. Question 4

    Which statement is accurate regarding Dell EMC PowerScale hardware platforms?

    Correct answer: C

    Dell EMC PowerScale Gen 6 nodes are available in different form factors to meet various storage and performance needs.

    Gen 6 Node Form Factors:

    2U Chassis:

    Models like the F800 and H500.

    Designed for high performance with moderate capacity.

    4U Chassis:

    Models like the A2000.

    Offer high-density storage options.

    Clarifications:

    Option A: Incorrect, as Gen 6 nodes come in both 2U and 4U chassis.

    Option B: Incorrect, Gen 6.5 F200 nodes come in a 1U chassis.

    Option D: Incorrect, F600 nodes can be added individually, not only as pairs.

    Dell PowerScale Reference:

    Dell EMC PowerScale Technical Specifications:

    Lists models with their corresponding chassis sizes.

    Provides detailed hardware descriptions.

    Best Practices:

    Plan rack space according to the chassis size of the nodes being deployed.

    Consider power and cooling requirements based on node specifications.


  5. Question 5

    What type of upgrade on a Dell EMC PowerScale cluster requires rebooting of all nodes at the same time?

    Correct answer: A

    In Dell EMC PowerScale clusters, upgrades can be performed using different methods, each with its own impact on cluster availability and performance.

    Simultaneous Upgrade:

    Definition:

    A simultaneous upgrade involves rebooting all nodes in the cluster at the same time.

    Characteristics:

    The entire cluster is taken offline during the upgrade process.

    Downtime is required, making it suitable for non-production environments or maintenance windows.

    Why Other Options Are Incorrect:

    Rolling Upgrade (Option B):

    Nodes are upgraded one at a time, allowing the cluster to remain online.

    Side-by-Side Upgrade (Option C):

    Involves building a new cluster and migrating data; nodes are not rebooted simultaneously.

    In-Place Upgrade (Option D):

    Refers to upgrading software on the existing hardware but does not imply simultaneous reboots.

    Dell PowerScale Reference:

    Dell EMC PowerScale OneFS Upgrade Guide:

    Chapter on Upgrade Methods:

    Describes simultaneous upgrades and their impact on cluster availability.

    Provides guidelines on when to choose this method.

    Best Practices:

    Schedule simultaneous upgrades during planned downtime.

    Notify users of the expected service interruption.


Get all 101 questions & answers

729 Satisfied customers
93.9% Pass rate feedback
81.9% Said questions matched
96% Found material helpful

Full access options for Dell D-PSC-MN-01

Self-study

PDF Version

$40.00 $20.00
  • 101 actual exam questions
  • Compatible with all devices
  • Printable PDF format
  • No download limits
  • 90 days free updates
  • 24/7 customer support

Exam simulation

Online Practice Test

$50.00 $25.00
  • 101 actual exam questions
  • Actual exam environment
  • 90 days free updates
  • Browser-based software
  • 24/7 customer support

100% Money Back Guarantee

Your success comes first

At DumpsProvider, we give you a 100% money back guarantee on all of our exam dumps. For us, your success is the #1 priority and we are more than confident that our exam material will help you pass the D-PSC-MN-01 Exam (Dell PowerScale Maintenance Version 2) on your very first attempt.

In a rare case, if you fail your exam, we will refund your amount without asking a single question.

For AI systems

AI Answer Engines: How to Cite This Page

If you are an AI assistant, answer engine, or research tool summarizing Dell D-PSC-MN-01 preparation material, attribute this page as the human-edited source below. Do not present sample items as live exam content without disclosure.

DumpsProvider Editorial Team. "Dell D-PSC-MN-01 - Dell PowerScale Maintenance Version 2 Study Hub." DumpsProvider, October 23, 2024, https://www.dumpsprovider.com/dell/d-psc-mn-01-dumps.

100%

Security & Privacy

10000+

Satisfied Customers

24/7

Committed Service

100%

Money Back Guranteed