- 70 Actual Exam Questions
- Compatible with all Devices
- Printable Format
- No Download Limits
- 90 Days Free Updates
Get All AI Networking Exam Questions with Validated Answers
| Vendor: | NVIDIA |
|---|---|
| Exam Code: | NCP-AIN |
| Exam Name: | AI Networking |
| Exam Questions: | 70 |
| Last Updated: | December 14, 2025 |
| Related Certifications: | NVIDIA-Certified Professional |
| Exam Tags: | Advanced NVIDIA Network EngineersData center administratorsand Storage administrators |
Looking for a hassle-free way to pass the NVIDIA AI Networking exam? DumpsProvider provides the most reliable Dumps Questions and Answers, designed by NVIDIA certified experts to help you succeed in record time. Available in both PDF and Online Practice Test formats, our study materials cover every major exam topic, making it possible for you to pass potentially within just one day!
DumpsProvider is a leading provider of high-quality exam dumps, trusted by professionals worldwide. Our NVIDIA NCP-AIN exam questions give you the knowledge and confidence needed to succeed on the first attempt.
Train with our NVIDIA NCP-AIN exam practice tests, which simulate the actual exam environment. This real-test experience helps you get familiar with the format and timing of the exam, ensuring you're 100% prepared for exam day.
Your success is our commitment! That's why DumpsProvider offers a 100% money-back guarantee. If you don’t pass the NVIDIA NCP-AIN exam, we’ll refund your payment within 24 hours no questions asked.
Don’t waste time with unreliable exam prep resources. Get started with DumpsProvider’s NVIDIA NCP-AIN exam dumps today and achieve your certification effortlessly!
[Spectrum-X Configuration]
You are automating the deployment of a Spectrum-X network using Ansible. You need to ensure that the playbooks can handle different switch models and configurations efficiently.
Which feature of the NVIDIA NVUE Collection helps simplify the automation by providing pre-built roles for common network configurations?
The NVIDIA NVUE Collection for Ansible includes pre-built roles designed to streamline automation tasks across various switch models and configurations. These roles encapsulate common network configurations, allowing for efficient and consistent deployment.
By utilizing these roles, network administrators can:
Apply standardized configurations across different devices.
Reduce the complexity of playbooks by reusing modular components.
Ensure consistency and compliance with organizational policies.
This approach aligns with Ansible best practices, promoting maintainability and scalability in network automation.
[Spectrum-X Troubleshooting]
You're troubleshooting a Spectrum-X network and notice that the System Status LED on a switch is blinking for more than 5 minutes. What is the most likely cause of this issue?
According to the NVIDIA Spectrum-X Switch Operating System (SX_OS) Troubleshooting Guide, the System Status LED behavior is a critical indicator of the switch's internal operational state.
From the document:
''The System Status LED will blink green during system initialization. If the LED continues blinking for more than 5 minutes, it indicates that the Onyx OS has failed to load properly. The system may be stuck in the boot process, or the file system may be corrupted.''
This blinking LED beyond normal initialization time indicates that the system has either encountered a failure during software boot or is unable to transition from bootloader to the OS runtime environment (i.e., Onyx).
Key causes include:
Corrupted or missing system files.
Failed firmware or OS upgrade attempts.
Boot device (e.g., eMMC or SSD) issues or corrupted partitions.
Technically, during power-on:
The switch performs POST (Power-On Self Test).
Then the Onyx OS attempts to load from the boot partition.
If the Onyx OS kernel or root filesystem is invalid, the system halts boot, and the LED remains in a blinking state, as no successful OS load confirmation is triggered.
Remediation Steps (as per NVIDIA guide):
Access the switch through console and monitor boot logs.
Use ONIE recovery or re-flash a stable Onyx OS version.
Check system storage integrity using built-in diagnostics.
Exact Extract Reference:
Source: NVIDIA SX_OS 3.9.3000 Documentation
Topic: Troubleshooting System Status LED
Extract: 'If the LED blinks for more than 5 minutes and the switch is not accessible via CLI, the Onyx software failed to load properly and recovery procedures must be initiated.'
=============
[Spectrum-X Optimization]
Which component of the Spectrum-X platform is responsible for reordering out-of-order packets?
Within the Spectrum-X platform, the NVIDIA BlueField-3 SuperNIC is responsible for reordering out-of-order packets. When RoCE adaptive routing is employed, packets may arrive at their destination out of order due to dynamic path selection. The BlueField-3 SuperNIC handles this by reassembling the packets in the correct order at the transport layer, ensuring that the application receives data seamlessly.
Reference Extracts from NVIDIA Documentation:
'As different packets of the same flow travel through different paths of the network, they may arrive out of order to their destination. At the RoCE transport layer, the BlueField-3 DPU takes care of the out-of-order packets and forwards the data to the application in order.'
'The BlueField-3 SuperNIC offers adaptive routing, out-of-order packet handling and optimized congestion control.'
The NVIDIA Spectrum-X networking platform is an Ethernet-based solution optimized for AI workloads, combining Spectrum-4 switches, BlueField-3 SuperNICs, and software like DOCA and NetQ to deliver high performance, low latency, and efficient data transfer. A key feature of Spectrum-X is its adaptive routing, which dynamically selects the least-congested paths for packet transmission to maximize bandwidth and minimize latency. However, this per-packet load balancing can result in packets arriving out of order at the destination, necessitating a mechanism to reorder them for seamless application performance. The question asks which Spectrum-X component is responsible for reordering these out-of-order packets.
According to NVIDIA's official documentation, the BlueField-3 SuperNIC is the component responsible for reordering out-of-order packets in the Spectrum-X platform. The SuperNIC, a network accelerator designed for hyperscale AI workloads, handles packet reordering at the RDMA over Converged Ethernet (RoCE) transport layer. It uses its processing capabilities to transparently reorder packets and place them in the correct sequence in the host memory, ensuring that adaptive routing's out-of-order delivery is invisible to the application. This is critical for maintaining predictable performance in AI workloads, particularly for GPU-to-GPU communication in Spectrum-X networks.
Exact Extract from NVIDIA Documentation:
''The Spectrum-4 switches are responsible for selecting the least-congested port for data transmission on a per-packet basis. As different packets of the same flow travel through different paths of the network, they may arrive out of order to their destination. The BlueField-3 SuperNIC transforms any out-of-order data at the RoCE transport layer, transparently delivering in-order data to the application.''
--- NVIDIA Technical Blog: Turbocharging Generative AI Workloads with NVIDIA Spectrum-X Networking Platform
This extract confirms that option A, the SuperNIC (specifically the BlueField-3 SuperNIC), is the correct answer. The SuperNIC's role in reordering packets ensures that the adaptive routing implemented by Spectrum-4 switches does not compromise application performance, maintaining high effective bandwidth and low tail latency for AI workloads.
[InfiniBand Configuration / Benchmarking]
When utilizing the ib_write_bw tool for performance testing, what does the -S flag define?
From NVIDIA Performance Tuning Guide (ib_write_bw Tool Usage):
'-S <SL>: Specifies the Service Level (SL) to use for the InfiniBand traffic. SL is used for setting priority and mapping to virtual lanes (VLs) on the IB fabric.'
This flag is useful when testing QoS-aware setups or validating SL/VL mappings.
Incorrect Options:
A -- No such flag for burst size.
B -- -q defines number of QPs.
C -- --rate or -R is used for rate-limiting.
[InfiniBand Configuration]
When designing a multi-tenancy East/West (E/W) fabric using Unified Fabric Manager (UFM), which method should be used?
In InfiniBand networks, Partitioning using Partition Keys (PKeys) is the standard method for implementing multi-tenancy and traffic isolation. PKeys allow administrators to define logical partitions within the fabric, ensuring that traffic is confined to designated groups of nodes. This mechanism is essential for creating secure and isolated environments in multi-tenant architectures.
The Unified Fabric Manager (UFM) leverages PKeys to manage these partitions effectively, enabling administrators to assign and control access rights across different tenants. This approach ensures that each tenant's traffic remains isolated, maintaining both security and performance integrity within the shared fabric.
Security & Privacy
Satisfied Customers
Committed Service
Money Back Guranteed