  1. 1 Question 1 Single choice Building Plan Review

    A plan reviewer is evaluating a proposed three-story office building that will also contain a ground-floor restaurant seating 180 occupants. The architect lists the entire structure as a single Business occupancy to minimize the number of required fire-resistance-rated separations. The restaurant kitchen exhaust and cooking appliances are shown on the mechanical sheets, and the restaurant floor area is about 4,500 square feet. The jurisdiction adopts the model code and does not allow reliance on the architect's occupancy argument without supporting analysis. Which action should the plan reviewer take FIRST?

  2. 2 Question 2 Single choice Site Plan Review

    A developer proposes a 40-unit residential complex on a site with a single cul-de-sac entrance. The dead-end fire apparatus access road will exceed 300 feet from the nearest public road to the farthest building entry. The site plan shows a 20-foot-wide drive, and the local amendments require a turnaround for dead-end roads over 150 feet. The developer asks that the turnaround be omitted because the trash truck already turns around in the cul-de-sac. The fire marshal's office has no approved alternative means of protection on file for this site. What should the plan reviewer require?

  3. 3 Question 3 Single choice Fire Protection and Life Safety Systems Review

    A plan reviewer is checking a submitted sprinkler layout for a light-hazard office floor. The design sheet shows standard upright sprinklers with a 15-foot spacing between heads along the branch lines, and the ceiling is a 9-foot suspended acoustical grid with recessed lighting. The reviewer's checklist includes spacing, obstruction, and the relationship between the sprinkler deflector and the ceiling plane. The submitted calculations are based on an inflow rate for the entire floor area. Which deficiency must the reviewer document as the primary concern?

  4. 4 Question 4 Single choice General Knowledge

    During a deposition arising from a lawsuit over a high-rise apartment fire, the plaintiff's attorney asks a fire plan examiner whether the approved plans showed compliance with the fire code. The examiner recalls that the plans were approved under an earlier edition of the code adopted by the jurisdiction at the time of permitting. The current edition has since been adopted with stricter requirements for corridor fire-resistance ratings. The attorney asks the examiner to state whether the building 'met the code today.' The examiner's department has asked to be consulted before any opinion is given outside the review record. What is the BEST response?

  5. 5 Question 5 Single choice Administrative

    A plan reviewer completes a review of a commercial kitchen remodel and identifies four deficiencies: a missing hood suppression system detail, an unmarked exit sign location, an incorrect occupant load calculation, and an absent fire-rated enclosure for a shaft. The jurisdiction requires that corrections be communicated in a single written report that cites the specific code section for each deficiency and that the submitter be given an opportunity to resubmit. The submitter has asked for the list to be sent by phone to save time. Which action should the reviewer take?

  6. 6 Question 6 Single choice Fire Protection and Life Safety Systems Review

    A fire plan examiner is reviewing a pre-engineered clean-agent suppression system for a telecommunications room. The submitted plans show the agent cylinders located inside the protected room, the discharge nozzles positioned 6 feet above the floor, and a manual release station mounted outside the room at the exit door. The manufacturer's listing specifies that the cylinders must be located outside the hazard or in an approved enclosure, and that the system must include a pre-discharge alarm with a delay before release. The plans do not show the delay device. Which deficiency is the reviewer's FIRST and most significant finding?

  7. 7 Question 7 Drag and drop Site Plan Review

    A plan reviewer is evaluating a proposed 180,000-square-foot warehouse with a sprinkler system and a 12-inch private fire service main. The site plan shows the hydrants placed along the south property line only, and the fire flow test data is 2,200 gpm at 20 psi residual from a hydrant 350 feet from the building's east wall. Match each requirement to the review action that addresses it.

    Drag each item onto its matching target. On a phone: tap an item, then tap a target.

    Hydrant location relative to the east wall
    Hydrant spacing for a required fire flow of 3,000 gpm
    Fire flow test data showing 2,200 gpm available
    Confirm the warehouse occupancy classification is Storage and not Business
    Confirm the test hydrant's distance and location is representative of the building's supply point
    Require a second turnaround at the south access road
    Verify hydrant distances along approved access so each building face is within the required hydrant spacing
    Compare available flow to required fire flow and require a corrected water supply if it is insufficient
  8. 8 Question 8 Drag and drop Building Plan Review

    A plan reviewer is evaluating a proposed four-story residential building of Type VA construction with a sprinkler system. The architect's drawings show the building height and story count, and the structural notes list combustible wood framing. The reviewer must confirm that each characteristic aligns with the construction type and the permitted height and area. Match each design characteristic to the review check that verifies it.

    Drag each item onto its matching target. On a phone: tap an item, then tap a target.

    Total building area shown on the floor plans
    Number of stories shown on the elevation drawings
    Structural notes specifying combustible wood framing
    Confirm the egress width required for the occupant load per floor
    Compare the story count to the limit for the stated construction type and occupancy
    Confirm the framing materials meet the fire-resistance rating required for the stated construction type
    Verify the fire alarm notification appliance spacing on each floor
    Check area against the allowable area for the construction type with sprinkler increases applied
  9. 9 Question 9 Order list Fire Protection and Life Safety Systems Review

    A fire plan examiner receives a submission for a new three-story mixed-use building with a standpipe system and a fire pump. The reviewer must evaluate the standpipe and pump design before approval and document any deficiencies. Arrange the steps in the order they must be performed.

    Drag the steps into the correct order, or use the arrows.

    1. Document each deficiency with the applicable code section and return it to the submitter for correction
    2. Compare the standpipe pressure and flow requirements against the hydraulic calculations submitted for the system
    3. Confirm the fire pump suction supply and the flow test data are sufficient for the calculated demand
    4. Verify the standpipe riser locations and hose connection positions against the required access and stair locations
  10. 10 Question 10 Multiple choice General Knowledge

    A fire plan examiner is asked to determine which codes and standards apply to a proposed hospital wing that includes a smoke control system, a generator-backed emergency power system, and sprinkler protection in patient areas. The jurisdiction has adopted the model codes and local amendments. Which TWO actions best ensure that the correct references are made in the review findings? (Choose two.)

  11. 11 Question 11 Dropdown Site Plan Review

    A plan reviewer is checking a fire flow requirement for a proposed 60,000-square-foot Type IIB storage building with automatic sprinklers. The jurisdiction's fire flow table lists the required flow based on the building's area and construction, and the reviewer records the requirement and the test result in the review notes. Complete the review note by selecting the correct value for each blank.

    Choose the correct value for each blank.

    Required fire flow: gpm. Available flow from the hydrant test: gpm. Result: the available flow the required fire flow.
  12. 12 Question 12 Dropdown Building Plan Review

    A plan reviewer is verifying the occupancy classification of a proposed building that will house a daycare for 60 children on the ground floor and offices above. The architect labels the whole building Business occupancy. The reviewer records the correct classification and the reason for it in the review notes. Complete the note by selecting the correct value for each blank.

    Choose the correct value for each blank.

    Ground floor occupancy: . Reason: a daycare with more than persons is classified as use under the model code.

These are 12 of the 100 questions in the full CFPE pack.

Get All 100 Questions

Get all 100 questions & answers

722 Satisfied customers
93% Pass rate feedback
83.1% Said questions matched
96% Found material helpful

Full access options for NFPA CFPE

Self-study

PDF Version

$40.00 $20.00
  • 100 actual exam questions
  • Compatible with all devices
  • Printable PDF format
  • No download limits
  • 90 days free updates
  • 24/7 customer support

Exam simulation

Online Practice Test

$50.00 $25.00
  • 100 actual exam questions
  • Actual exam environment
  • 90 days free updates
  • Browser-based software
  • 24/7 customer support

100% Money Back Guarantee

Your success comes first

At DumpsProvider, we give you a 100% money back guarantee on all of our exam dumps. For us, your success is the #1 priority and we are more than confident that our exam material will help you pass the CFPE Exam (Certified Fire Plan Examiner) on your very first attempt.

In a rare case, if you fail your exam, we will refund your amount without asking a single question.

100%

Security & Privacy

10000+

Satisfied Customers

24/7

Committed Service

100%

Money Back Guranteed