Exam Information
Free practice questions with explanations
Hitachi Vantara HQT-4180 Practice Questions
Answer a question to see the correct answer and the explanation, or click Show answer. Newest questions first.
- Questions
- 13
- Answered
- 0
- Correct
- 0
- Score
- -
-
1 Question 1 Single choice Section 1 System architecture
A regional hospital is replacing an aging midrange array with a VSP midrange model. The planning team must size the new system for 180 TB of usable capacity in a single rack footprint, with the ability to add front-end ports later without downtime. The team has been comparing models by maximum drive count and cache, but the purchasing manager wants to avoid overbuying. Which action should the architect take FIRST to select the correct model?
Correct Answer: CExplanationUsable capacity is determined by raw drive capacity minus RAID parity overhead and spare drives, constrained by the drive types and enclosure counts each midrange model supports. Sizing against maximum raw figures or cache leads to overbuying, which the purchasing manager wants to avoid. Choosing the largest model and trimming later ignores the footprint constraint and the sparing policy. Selecting on front-end port count addresses connectivity, not capacity, so it does not answer the sizing question.
-
2 Question 2 Single choice Section 1 System architecture
A company operates two VSP midrange systems in a metro cluster design. During a capacity review, the storage team notes that controller-to-controller communication uses the internal backplane and that the cache is mirrored between the two controllers. A junior administrator asks why a controller failure does not cause loss of unwritten host data. Which internal architecture behaviour explains this?
Correct Answer: CExplanationOn VSP midrange systems, cache is mirrored across the controllers, and a write is acknowledged to the host only after it exists in both controllers' cache. That is why losing one controller does not lose acknowledged writes. Acknowledging after drive commit would be slower and is not the design. Independent cache copies with no mirroring would lose data on failure, and a periodic flush to a system disk does not describe the write acknowledgement path.
-
3 Question 3 Single choice Section 2 Back-end Architecture
A storage engineer is planning the drive expansion of a VSP midrange system. The current configuration uses RAID-6 parity groups across two drive enclosures. A new enclosure of the same type is being added, and the engineer wants to keep data evenly distributed and preserve the ability to survive a single enclosure failure without data loss. The change window is limited, and the team cannot migrate existing volumes. Which plan best satisfies these requirements?
Correct Answer: CExplanationProtecting against a single enclosure failure requires that each parity group has at most one member per enclosure, so the parity stripe remains recoverable. Spreading new group members across enclosures meets this and avoids a volume migration. Building groups entirely inside the new enclosure creates a single point of failure for those groups. Concentrating spares or adding members within one enclosure both undermine enclosure-level protection and the evenness requirement.
-
4 Question 4 Single choice Section 2 Back-end Architecture
A VSP midrange system reports that a drive has failed in a RAID-6 parity group. A dedicated hot spare exists in the same drive box, and the system begins a copy-back-free sparing operation. The operations lead asks whether the hot spare must be physically replaced before the array returns to full protection. The team wants to minimise time spent in a degraded state. Which action is correct?
Correct Answer: CExplanationDynamic sparing lets the hot spare rebuild the failed member immediately, restoring redundancy without waiting for hardware replacement. Afterward the failed drive is replaced and the sparing relationship is cleared so the spare is available again. Waiting for replacement extends degradation, and disabling the group would cause an outage. Converting RAID levels mid-failure is not a sparing step and adds risk.
-
5 Question 5 Single choice Section 3 System Installation
A systems integrator is preparing to install a new VSP midrange system at a manufacturing site. The site already has a VSP midrange system in production, and the customer wants the new system to receive a clean configuration with its own serial-based identity and no inherited host groups or LDEV mappings. The integrator's checklist calls for a procedure that initializes the configuration from scratch. Which installation procedure should the integrator select?
Correct Answer: CExplanationThe New Installation procedure is the one used when a system is being set up as a fresh installation, with no inherited configuration from another system. Restoring a configuration file would copy production settings, violating the clean-configuration requirement. Microcode upgrades and enclosure additions both work on an existing configuration and do not reset it.
-
6 Question 6 Single choice Section 3 System Installation
During the installation of a VSP midrange system, the field engineer completes the hardware cabling and powers on the storage system. The customer's SAN team reports that hosts cannot see any ports on the new array after zoning is applied. The engineer wants to confirm that the port configuration is correct before troubleshooting the fabric. Which step should the engineer perform next?
Correct Answer: DExplanationBefore blaming the fabric or the hosts, the engineer should confirm the front-end port configuration on the array (port type and mode) against the connectivity plan from the installation worksheet. A misconfigured port mode can make the port invisible or unusable. Multipath reinstallation addresses host drivers, not array port visibility. Recreating LDEVs does not affect port discovery, and fabrics do not need restarting to apply zoning.
-
7 Question 7 Single choice Section 3 System Installation
A customer purchases a VSP midrange system and plans to enable a program product for local replication and a second one for encryption. The first license key was entered during the initial configuration and the replication function works. Later, the encryption feature shows as not licensed, even though the purchase order lists it. The administrator wants to enable the feature without disrupting production I/O. Which action is correct?
Correct Answer: DExplanationProgram product licenses are enabled by installing the license key through the management interface, and additional keys can be added to a running system without affecting host I/O. Reinstalling microcode is unnecessary and risky. Deleting a working license risks disrupting replication, and licenses are not restricted to batch entry. Shipping the array is not required for key installation.
-
8 Question 8 Single choice Section 3 System Installation
A storage administrator is reviewing the documentation package for a VSP midrange installation. The team needs to determine which documents describe the required physical sequence for rack mounting, power connection and initial cabling, and which describe the post-installation configuration of spare drive policy. The administrator wants the correct sources before a change request is filed. Which pairing of document type and content is correct?
Correct Answer: DExplanationPhysical installation steps including rack placement, power and cabling are documented in the installation guide, while logical configuration tasks such as spare drive policy belong in the configuration or operations documentation. Release notes describe changes between versions, not physical procedure, and license files only hold entitlement data. The other pairings mismatch document purpose with content.
-
9 Question 9 Single choice Section 1 System architecture
A company is considering a VSP midrange model for a virtualized environment. The workload analysis shows sustained random write I/O at peak and a requirement to keep latency low during drive rebuilds. The architect is comparing a model whose controller cache is generous but whose drive-side back-end bandwidth is lower against a model with a smaller cache and a higher back-end bandwidth. Which factor should drive the decision, given that rebuild traffic competes with host I/O on the back end?
Correct Answer: AExplanationDuring a rebuild, reconstruction reads and writes compete with host I/O for drive-side back-end bandwidth, so the architecture with higher back-end throughput better protects latency under the stated workload. Cache helps absorb write bursts but does not remove back-end contention for rebuilds. Front-end port count governs host connectivity, not drive-side rebuild traffic. Claiming back-end bandwidth is irrelevant ignores the contention the scenario describes.
-
10 Question 10 Single choice Section 2 Back-end Architecture
A storage team is designing the drive protection for a VSP midrange system that will hold large-capacity nearline drives. Rebuild times for high-capacity drives are long, and the business requires that a second drive failure during a rebuild does not cause data loss within the parity group. Cost constraints rule out additional drive capacity for mirroring. Which parity configuration best meets the requirement?
Correct Answer: AExplanationRAID-6 maintains protection through a second drive failure during the extended rebuild window of large nearline drives, which the requirement demands without mirroring's capacity cost. RAID-5 with a spare still leaves only single-failure protection during the rebuild. RAID-0 has no redundancy, and RAID-1 is ruled out by the explicit capacity cost constraint.
-
11 Question 11 Multiple choice Section 3 System Installation
A field engineer is preparing a new VSP midrange system for handover. Several initial configuration tasks remain. Which TWO actions are appropriate during initial configuration and program product enablement? (Choose two.)
Correct Answer: B, DExplanationProgram products are activated by entering the license keys, and their enabled status should be verified in the management interface before relying on them for host volumes. Restoring another system's configuration would import unwanted settings into a new installation. Disabling spares removes protection, which is unacceptable. Powering off controllers after each license is unnecessary and disruptive.
-
12 Question 12 Multiple choice Section 2 Back-end Architecture
A storage administrator is investigating intermittent performance degradation on a VSP midrange system. The back-end monitoring shows high utilization on one drive path and occasional drive errors in one enclosure. The administrator must find the most appropriate responses that improve resilience without causing an outage. Which TWO actions are appropriate? (Choose two.)
Correct Answer: B, DExplanationInspecting the enclosure and back-end path health identifies the failing hardware, and confirming cabling and path redundancy addresses a common cause of intermittent drive-path errors while keeping the array online. Shutting down the array causes an outage and is unnecessary. Removing parity groups is destructive and infeasible. Cache size does not correct hardware-level drive path faults.
-
13 Question 13 Multiple choice Section 1 System architecture
An architect is reviewing a proposal to deploy VSP midrange storage across two sites for a bank. The design must keep write acknowledgements safe during a single controller failure and must be sized to remain within the bank's power budget. Which TWO statements about the architecture and specifications support the proposal? (Choose two.)
Correct Answer: C, EExplanationMirroring cache across controllers is what protects acknowledged writes during a controller failure, and power planning must use the specification for the exact configuration, since power depends on the installed hardware. Disabling mirroring to acknowledge from a single cache would sacrifice the protection the bank requires. Claiming capacity and power scale linearly with controllers is inaccurate, and cache plays a role in write protection, so ignoring it is wrong.
These are 13 of the 35 questions in the full HQT-4180 pack.
Get All 35 QuestionsGet all 35 questions & answers
Full access options for Hitachi Vantara HQT-4180
Self-study
PDF Version
- 35 actual exam questions
- Compatible with all devices
- Printable PDF format
- No download limits
- 90 days free updates
- 24/7 customer support
Best value
Bundle Pack
- Discounted PDF + online access
- 35 actual exam questions
- Both PDF and online practice test
- Free 90 days updates
- No download or practice limits
- 24/7 customer support
Exam simulation
Online Practice Test
- 35 actual exam questions
- Actual exam environment
- 90 days free updates
- Browser-based software
- 24/7 customer support
100% Money Back Guarantee
Your success comes first
At DumpsProvider, we give you a 100% money back guarantee on all of our exam dumps. For us, your success is the #1 priority and we are more than confident that our exam material will help you pass the HQT-4180 Exam (Hitachi Vantara Qualified Professional - VSP Midrange Family Installation) on your very first attempt.
In a rare case, if you fail your exam, we will refund your amount without asking a single question.