Dell EMC D-PEXE-IN-A-00 Exam Dumps

Get All Dell PowerEdge XE9680 and XE8640 Install Exam Questions with Validated Answers

D-PEXE-IN-A-00 Pack
Vendor: Dell EMC
Exam Code: D-PEXE-IN-A-00
Exam Name: Dell PowerEdge XE9680 and XE8640 Install
Exam Questions: 14
Last Updated: September 7, 2025
Related Certifications: PowerEdge
Exam Tags:
Gurantee
  • 24/7 customer support
  • Unlimited Downloads
  • 90 Days Free Updates
  • 10,000+ Satisfied Customers
  • 100% Refund Policy
  • Instantly Available for Download after Purchase

Get Full Access to Dell EMC D-PEXE-IN-A-00 questions & answers in the format that suits you best

PDF Version

$60.00
$36.00
  • 14 Actual Exam Questions
  • Compatible with all Devices
  • Printable Format
  • No Download Limits
  • 90 Days Free Updates

Discount Offer (Bundle pack)

$80.00
$48.00
  • Discount Offer
  • 14 Actual Exam Questions
  • Both PDF & Online Practice Test
  • Free 90 Days Updates
  • No Download Limits
  • No Practice Limits
  • 24/7 Customer Support

Online Practice Test

$50.00
$30.00
  • 14 Actual Exam Questions
  • Actual Exam Environment
  • 90 Days Free Updates
  • Browser Based Software
  • Compatibility:
    supported Browsers

Pass Your Dell EMC D-PEXE-IN-A-00 Certification Exam Easily!

Looking for a hassle-free way to pass the Dell EMC Dell PowerEdge XE9680 and XE8640 Install exam? DumpsProvider provides the most reliable Dumps Questions and Answers, designed by Dell EMC certified experts to help you succeed in record time. Available in both PDF and Online Practice Test formats, our study materials cover every major exam topic, making it possible for you to pass potentially within just one day!

DumpsProvider is a leading provider of high-quality exam dumps, trusted by professionals worldwide. Our Dell EMC D-PEXE-IN-A-00 exam questions give you the knowledge and confidence needed to succeed on the first attempt.

Train with our Dell EMC D-PEXE-IN-A-00 exam practice tests, which simulate the actual exam environment. This real-test experience helps you get familiar with the format and timing of the exam, ensuring you're 100% prepared for exam day.

Your success is our commitment! That's why DumpsProvider offers a 100% money-back guarantee. If you don’t pass the Dell EMC D-PEXE-IN-A-00 exam, we’ll refund your payment within 24 hours no questions asked.
 

Why Choose DumpsProvider for Your Dell EMC D-PEXE-IN-A-00 Exam Prep?

  • Verified & Up-to-Date Materials: Our Dell EMC experts carefully craft every question to match the latest Dell EMC exam topics.
  • Free 90-Day Updates: Stay ahead with free updates for three months to keep your questions & answers up to date.
  • 24/7 Customer Support: Get instant help via live chat or email whenever you have questions about our Dell EMC D-PEXE-IN-A-00 exam dumps.

Don’t waste time with unreliable exam prep resources. Get started with DumpsProvider’s Dell EMC D-PEXE-IN-A-00 exam dumps today and achieve your certification effortlessly!

Free Dell EMC D-PEXE-IN-A-00 Exam Actual Questions

Question No. 1

A deployment engineer is installing eight PowerEdge XE9680 servers. Two servers will be installed in each of four racks. The data center managers must plan for the power needed to supply power to

the four racks.

What power consumption information can the deployment engineer give the data center manager?

Show Answer Hide Answer
Correct Answer: B

The PowerEdge XE9680 server is equipped with power supply units (PSUs) that are essential for its operation. Here's the power consumption information that the deployment engineer can provide:

PSU Specifications: Each PowerEdge XE9680 server comes withfour 2800-Watt, 15.6 Amp PSUs1. This specification is crucial for the data center manager to understand the power requirements for each server.

Total Power Requirement: With two servers per rack, each rack will have a total ofeight 2800-Watt PSUs. This information helps in calculating the total power draw for each rack.

Power Distribution Units (PDUs): While the number of PDUs required for high availability can vary, it's important to note that the server's PSUs feature aC22 input socket1. The data center manager should ensure that the PDUs in the rack are compatible with this type of connection.

Power Planning: The data center manager must plan for the power needed to supply power to the four racks, considering the power draw of the servers and any additional equipment that will be installed.

By providing this detailed power consumption information, the deployment engineer assists the data center manager in planning for the appropriate power infrastructure to support the PowerEdge XE9680 servers.


Question No. 2

A deployment engineer installed and powered on a XE8640 server. The Linux operating system is installed. They need to update the drivers on the server.

What is a consideration before updating the driver?

Show Answer Hide Answer
Correct Answer: B

Understanding GPU Drivers:

Graphics Processing Units (GPUs) require specific drivers to ensure optimal performance and compatibility with the operating system. Each GPU model typically has a unique driver package designed to leverage its capabilities and architecture.

Driver Packages for Different GPU Models:

For the Dell PowerEdge XE8640, which may be equipped with multiple GPU models, it is crucial to identify the exact GPU models installed in the server. Each GPU model, whether it's from NVIDIA, AMD, or another manufacturer, will have a distinct driver package.

Importance of Model-Specific Drivers:

Using the correct driver for each GPU model ensures that the GPU operates efficiently, provides the intended performance, and remains stable under various workloads. Incorrect drivers can lead to suboptimal performance, compatibility issues, or system instability.

Steps to Update Drivers on Linux:

Identify the GPU models installed in the server. This can be done using commands like lspci | grep -i vga or similar tools that list the hardware components.

Visit the GPU manufacturer's website (e.g., NVIDIA, AMD) to download the appropriate drivers for each GPU model.

Follow the manufacturer's installation instructions, which typically involve downloading the driver package, extracting it, and running an installation script or using package management tools.

Using iDRAC for Driver Updates:

While the iDRAC (Integrated Dell Remote Access Controller) UI can be used for various management tasks, uploading driver packages directly via iDRAC is not typically supported. Drivers are usually installed within the operating system environment.

Compatibility with Linux:

Ensure that the driver package is compatible with the Linux distribution and kernel version installed on the XE8640. GPU manufacturers often provide detailed compatibility information and installation guides specific to various Linux distributions.

Reference to Official Documentation:

Dell's support site and the GPU manufacturer's documentation provide comprehensive guides on downloading and installing the correct drivers for various operating systems, including Linux.


Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on hardware configurations and driver installations.

NVIDIA/AMD Official Documentation: These resources offer specific instructions on downloading and installing GPU drivers for different operating systems and GPU models.

Question No. 3

A deployment engineer arrives on-site to install an XE9680 server. The server lift does not have the ability to maneuver beneath the XE9680 shipping pallet.

How many people must you have to physically pick up the server to place it on the lift shelf?

Show Answer Hide Answer
Correct Answer: A

Weight and Size of the PowerEdge XE9680:

The Dell PowerEdge XE9680 server is designed for high performance, which often results in a larger and heavier form factor. Handling such servers typically requires multiple people to ensure safety and prevent damage.

Ergonomic Considerations:

Due to its weight and size, it is crucial to follow proper ergonomic practices when lifting and moving the server. This minimizes the risk of injury and ensures the server is handled safely.

Number of People Required:

For the XE9680, it is recommended to have four people when physically picking up the server to place it on the lift shelf. This recommendation is based on the server's weight and the need to maneuver it safely onto the lift.

Safety and Coordination:

Each person should position themselves on one side of the server, ensuring an even distribution of weight. This coordinated effort helps in lifting the server evenly and reducing the risk of dropping or mishandling it.

Procedure for Lifting:

Two individuals should position themselves at the front corners, and two at the rear corners of the server. On a coordinated count, all four should lift the server together and place it gently onto the lift shelf.

The lift shelf should be stable and able to support the weight of the server once it is placed on it.

Using the Lift:

Once the server is on the lift shelf, it can be maneuvered into the desired position in the rack. Ensure that the lift is rated for the weight of the XE9680 to avoid any mechanical failures.

Reference to Official Documentation:

Dell's installation guides and service manuals typically provide guidelines on the number of personnel required for handling large and heavy servers, ensuring both safety and compliance with best practices.


Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides detailed guidelines on handling and installing the XE9680 server, including the recommended number of personnel required for safe handling.

Dell EMC Technical Specifications Guide: Offers insights into the physical dimensions and weight of the PowerEdge XE9680, informing the need for multiple personnel for safe handling and installation.

Question No. 4

A deployment engineer is discussing the benefits of the PowerEdge XE9680 to a data center manager. A customer has many PowerEdge servers. They require the greatest amount of network

throughput possible. The manager asks how many PCle risers and network PCI cards the server can support.

What should be the response?

Show Answer Hide Answer
Correct Answer: B

The PowerEdge XE9680 server supports a high level of network throughput, which is achieved through its PCIe risers and network PCI card capacity. Here's the detailed information:

PCIe Slots: The PowerEdge XE9680 server supports up to10 PCIe Gen5 slots1. These slots are used to install PCIe devices, including network cards, which are essential for achieving high network throughput.

Riser Cards: Riser cards are used in servers to extend the PCIe slots and make them more accessible for installing additional cards, such as network cards.

Network Card Support: Each riser can support multiple PCIe network cards, allowing for expansion and increased network throughput.

Configuration: For the greatest amount of network throughput, the server can be configured withfour risers, and each riser can accommodatetwo PCIe network cards1. This configuration maximizes the number of network cards and, consequently, the network throughput capability of the server.

By utilizing the full capacity of PCIe slots with the appropriate risers and network cards, the PowerEdge XE9680 can meet the customer's requirement for the highest network throughput possible.


Question No. 5

A deployment engineer is installing a PowerEdge XE8640 server in a rack with round holes. They cannot get the outer rail portion to fit flush with the rack frame.

What is the reason the outer rail is not flush with the frame?

Show Answer Hide Answer
Correct Answer: C

Understanding Rail Types and Compatibility:

Dell PowerEdge servers, including the XE8640, come with rail kits designed for specific types of racks. The rail kits are tailored to fit racks with square holes or threaded holes, depending on the model and configuration.

Compatibility with Round-Hole Racks:

The PowerEdge XE8640 does not support installation in round-hole racks. The rail kits provided with the XE8640 are designed for 4-post racks with square holes or 4-post threaded racks. Attempting to install these rails in a round-hole rack will result in improper fitment and stability issues.

Common Installation Issues:

If the outer rail portion does not fit flush with the rack frame, it is often due to a compatibility issue with the rack type. Round-hole racks require specific rail kits that are different from those used for square or threaded hole racks.

Verifying Rack Type:

Before installation, verify the type of rack being used. Ensure that it matches the specifications outlined in the server's installation guide. Using the correct rack type ensures proper fitment and structural integrity.

Alternative Solutions:

If the current rack is a round-hole type, consider using a compatible rack with square or threaded holes for the XE8640. Alternatively, there might be adapters or conversion kits available that allow the use of standard rails in round-hole racks, although these are not typically recommended due to potential stability issues.

Reference and Documentation:

Refer to the Dell EMC PowerEdge XE8640 Installation and Service Manual for detailed information on rail and rack compatibility. This manual provides specifications for supported rack types and instructions for proper installation.


Dell EMC PowerEdge XE8640 Installation and Service Manual: This document provides comprehensive guidelines on the correct installation procedures and compatible rack types for the XE8640 server.

Dell EMC Technical Specifications Guide: Offers detailed specifications on the rack compatibility and rail options for Dell PowerEdge servers, ensuring proper installation and fitment.

100%

Security & Privacy

10000+

Satisfied Customers

24/7

Committed Service

100%

Money Back Guranteed